Reflector replacement 

The HortiStar HR96 reflector is a precision high efficiency reflector that 

should be handled with care. If it is  damaged or deformed you should 

replace it. We recommend to change the reflector every year for optimal 

results. Replacement reflectors are available from your Gavita reseller.  

To replace the reflector remove the lamp first. Pull up the lever at the end 

of the reflector bracket while holding the reflector at that end. The reflector 

will unlatch and can be removed now.  When inserting the new reflector 

make sure the notches are in the appropriate holes. 

Always let your lamp 

and reflector cool down first before changing the reflector to prevent 

injuries. 

 

Using the lever to unlatch the reflector, aligning the notches with the reflector holes 

 

 

Maintenance

 

Keep the bracket clean from dust and dirt with a dry or damp cloth. When using a damp cloth please disconnect 

the power first. We recommend you check your electrical connections regularly: check if the plugs are inserted 

completely and don’t show any (contact) damage, check if the wiring is undamaged and that the wire ends 

connected to the reflector are tightly secured in their terminals. For stranded wire always use cable end sleeves.  

 

The Miro aluminum reflector should not be cleaned with any detergent or water, use a soft dry soft cloth to avoid 

scratching the material. Do not touch the reflective material. Replace the Miro reflector each year together with 

your lamp. Do not use sulfur vaporizers when lamps are operating and do not use sulfur vaporizers or water 

misters close to your reflectors. Sulfur and calcium deposit will damage your reflector and decrease the 

efficiency of your reflector. 

 

You can not clean the reflector without damaging it. Wiping it carefully with a soft cloth is the best you can do. 

Never use polishes, detergents, sprays or normal tap water when wiping your reflector. If you need a damp cloth, 

use a completely clean soft cloth with demi water only, or pure alcohol. 

 

We recommend to change your reflector once a year, together with the lamp. 

 

 

 

Troubleshooting 

If your lamp does not fire up first check if the lamp is inserted correctly before restarting. Then check all wires 

and connector. If all connections are correct and the lamp still does not start check the ballast or replace the 

lamp. 

 

Summary of Contents for Pro Series

Page 1: ...m width x 7 6 193 mm height Lamp holder Vossloh Schwabe k12 x 30s Reflector Gavita HortiStar HR 96 1000 Miro aluminium reflector Cable gland M20 Lamp cord Optional 4m with IEC or Wieland plug One of the best 1000 Watt HPS lamps in the market is the double ended Philips 1000W 400V EL lamp Specifically designed for high frequency electronic ballasts it has a connection at each side of the lamp hence do...

Page 2: ...e Miro Aluminum high efficiency reflector reflector HortiStar HR 96 1000 DE is replaceable without tools Due to the double ended nature of the lamp it must be removed before replacing the reflector The high quality of the used materials and precision of manufacturing result in 96 reflector efficiency which means that 96 of all light exiting the fitted lamp will reach your crop The EU version is st...

Page 3: ...ire to the center connection of the lamp so to the screw terminal with the white wire 1 To install the lamp cord 1 Locate the cover plate of the screw terminal and remove the 4 screws One of the screws has a tooth lock washer to make sure that the housing and the plate are electrically connected 2 Feed the lamp cord through the opened cable gland Do not tighten the cable gland yet 3 Make sure the ...

Page 4: ...ect your lamp cord to the ballast before switching it on When changing the lamp always disconnect the ballast from mains by removing the mains plug Let the lamp and reflector cool down for 20 minutes before changing as they can be very hot When replacing a defect lamp without disconnecting mains from an electronic ballast the new lamp may not start disconnecting the power will in many cases reset ...

Page 5: ...se pure alcohol and or wipe with a dry clean soft cloth Make sure the end wires are straight Open the lamp holders by sliding them outward Install the lamp with the getter see illustration at the side of the ballast with the glass vacuum seal pointed downward Press the lamp in the fitting until the metal springs hold the lamp Close the lamp holders by sliding them inward Wipe the lamp with a clean...

Page 6: ...s are inserted completely and don t show any contact damage check if the wiring is undamaged and that the wire ends connected to the reflector are tightly secured in their terminals For stranded wire always use cable end sleeves The Miro aluminum reflector should not be cleaned with any detergent or water use a soft dry soft cloth to avoid scratching the material Do not touch the reflective materi...

Page 7: ... lighted objects to prevent fire risk Warranty GAVITA Holland warrants the mechanical and electronic components of this product to be free of defects in material and workmanship if used under normal operating conditions for a period of three 3 years from the original date of purchase If the product shows any defects within this period and that defect is not due to user error or improper use GAVITA...

Reviews: