28
B C
A
15
Switching clock mode and setting the time
5.1.3.
Switch temperature units between
0
Fahrenheit and
0
Celsius
•
Press “enter”, the controller menu will open
•
Press the arrow keys
to locate “Temp units” and press “enter”.
The “temperature units” screen will open
•
Press the arrow keys
to switch between
0
F and
0
C. Press “enter” to
confirm your choice and return to the controller menu.
5.2.
Calibrating the temperature sensor(s)
Caution!
The controller will not immediately display the correct temperature
when the sensor is plugged in. The sensor will take some time to respond to
temperature changes.
Caution!
To allow for accurate temperature management within the
climate room, the temperature measured by the controller must match the
temperature measured by the climate control system. If these values do not
match, the temperature safety system of the Gavita controller may interfere
with the climate control system.
Caution!
Always place the temperature sensor of the controller as close as
possible to the temperature sensor of the climate control system.
If necessary, the temperature measured by the Gavita controller can be
adjusted to match the temperature measured by the climate control system.
•
Press “enter”, the controller menu will open
•
Press the arrow keys
to locate “Calibrate” and press “enter”.
The “Calibration” screen will open (16). This screen displays the temperature
measured by the main temperature sensor “T1” (16A) and auxiliary
temperature sensor“T2” (16B). If one or both temperature sensors are not or
incorrectly connected, the text “removed” or “failure” will be displayed behind
the applicable temperature sensor.