Gavita GAN Electronic 750 W Manual Download Page 6

8. 

Precautions when using the fixture

 Warning!

 Never use the fixture without a lamp or reflector!  

 Warning!

 Always wait 20 - 30 minutes for the reflector to cool down!

9. 

Troubleshooting using the status LED

 

 Note: 

The status LED is present at 400 V models only.

The status LED provides information on the condition of the lamp and electronic ballast. Consult table 1 to interpret the status 

LED. LED signals are represented by colored red dots.

9.1. 

Status indications

Status LED message 

Status fixture

Description

Action/Solution



No error

The lamp is working correctly

No action required. 



EOL timer expired

Maximum number of ignition attempts 

done without succesfull ignition or a 

driver is locked or has failed

Reset mains cycle manually. If the 

problem persists, it could be the end 

of the lamp’s lifecycle. Replace the 

lamp



Cycle error

Maximum number ignition attempts 

done (lamp stopped for unknown 

reason)

Check the lamp. Replace the lamp 

when damaged



Low mains

Mains voltage too low

Check the voltage, mains cycle 

automatically resets



Thermal overload

Maximum driver temperature  

exceeded

Reset mains cycle manually



Lamp voltage out  

of range

Lamp voltage too low, lamp voltage too 

high or DC shift detected

This could be the end of the lamp’s 

lifecycle. Replace the lamp



High mains

Mains voltage too high and/or DC-bus 

voltage too high

Check the voltage, mains cycle 

automatically resets

Ignition busy

Ballast is trying to ignite the lamp

No action required. 

Legend

LED message 

Time (approx.)

 

256 ms.



512 ms.

 Table 1

Summary of Contents for GAN Electronic 750 W

Page 1: ...en independently tested and certified to meet recognized standards for safety The symbol on the material accessories or packaging indicates that this product may not be discarded as household waste By disposing of the equipment in the proper way you will be helping to prevent possible risks to the environment and public health which might otherwise be caused by improper handling of the discarded e...

Page 2: ... 5x19 5cm height excl mounting hooks Temperature case 75 Celsius 167 Fahrenheit Temperature ambient 0 35 Celsius 32 95 Fahrenheit Relative humidity 70 not condensating Total Harmonic Distortion 10 Frequency 50 60 Hz Certification CSA 252952 Insulation Class 1 requires an earth connection Power inlet Wieland RST20i3 IP20 connector Ignition voltage 4 kV Earth leakage current 1 mA 3 3 Compatible prod...

Page 3: ...f at least 30 minutes before touching the lamp or reflector Touching the lamp or the reflector when the lamp is lit or immediately afterwards will result in severe burns Never touch the lamp with bare hands as this will cause damage to the lamp Do not use the fixture near flammable explosive or reactive substances The lamp and the reflector of the fixture reach temperatures of 85 Celsius 185 Fahre...

Page 4: ...tch off mains power Read the Gavita light distribution plan If not done already install the lamp in the fixture see paragraph 10 2 If not done already screw the mounting point into the fixture 3 7 2 Installing the fixture Mount the suspension bracket according to the light distribution plan Hang the fixture by its two mounting points onto the suspension bracket 4 The two mounting points are spaced...

Page 5: ...ot done already remove the top part of Wieland RST20i3 female connector from the bottom part 5 Pull the mains cable through the bottom part 6 Strip the wiring 7 The insulation strip length is 8 mm 0 31 and the dismantling length is 32 mm 1 26 Connect the wiring to the top part connections 8 Cable description Wire 277V 347V 400V Blue White Neutral N Phase N Brown Black Phase L Phase L Green Yellow ...

Page 6: ...cesfull ignition or a driver is locked or has failed Reset mains cycle manually If the problem persists it could be the end of the lamp s lifecycle Replace the lamp Cycle error Maximum number ignition attempts done lamp stopped for unknown reason Check the lamp Replace the lamp when damaged Low mains Mains voltage too low Check the voltage mains cycle automatically resets Thermal overload Maximum ...

Page 7: ...his will disappear when the lamp runs on full power If not replace the lamp Regularly check the wiring of the product to ensure it is undamaged 10 1 How to disconnect the Wieland RST20i3 plug Warning Do not connect or disconnect the Wieland RST20i3 plug under load Switch off mains power Press the pin on the Wieland RST20i3 male connection downwards and pull the Wieland RST20i3 female connection fr...

Page 8: ...e reflector are aligned with the pins in the fixture 19 Release the reflector lever so its two pins hold the reflector in place Insert the lamp in the lamp holder see paragraph 10 2 Switch on mains power 11 Storage and disposal Store the fixture in a dry and clean environment with an ambient temperature of 20 85 Celsius 4 185 Fahrenheit The product must not be discarded as unsorted municipal waste...

Reviews: