8.
Precautions when using the fixture
Warning!
Never use the fixture without a lamp or reflector!
Warning!
Always wait 20 - 30 minutes for the reflector to cool down!
9.
Troubleshooting using the status LED
Note:
The status LED is present at 400 V models only.
The status LED provides information on the condition of the lamp and electronic ballast. Consult table 1 to interpret the status
LED. LED signals are represented by colored red dots.
9.1.
Status indications
Status LED message
Status fixture
Description
Action/Solution
No error
The lamp is working correctly
No action required.
EOL timer expired
Maximum number of ignition attempts
done without succesfull ignition or a
driver is locked or has failed
Reset mains cycle manually. If the
problem persists, it could be the end
of the lamp’s lifecycle. Replace the
lamp
Cycle error
Maximum number ignition attempts
done (lamp stopped for unknown
reason)
Check the lamp. Replace the lamp
when damaged
Low mains
Mains voltage too low
Check the voltage, mains cycle
automatically resets
Thermal overload
Maximum driver temperature
exceeded
Reset mains cycle manually
Lamp voltage out
of range
Lamp voltage too low, lamp voltage too
high or DC shift detected
This could be the end of the lamp’s
lifecycle. Replace the lamp
High mains
Mains voltage too high and/or DC-bus
voltage too high
Check the voltage, mains cycle
automatically resets
Ignition busy
Ballast is trying to ignite the lamp
No action required.
Legend
LED message
Time (approx.)
256 ms.
512 ms.
Table 1