13
UP
DOWN
GND
Dry
Contact
Dry
Contact
Dry
Contact
DT
-ON/OF
F
COMMON
DO
MUTE
Dry
Contact
DT
-ON/OF
F
COMMON
DO
MUTE
MUTE
DOWN
COMMON
UP
Note:
The same functionality can be achieved by connecting terminals DT-
ON/OFF & DO to COMMON through a 3-way switch as shown in the picture
above.
Note:
Do not close simultaneously more than one dry contact. Operation
under this condition is not guaranteed.
MUTE Interface
When activating the MUTE interface, the
film will instantaneously toggle
into a translucent state. When deactivated, the
film will return to the
previous transparent state.
Dimmer
Frequency Switching
Gauzy’s
controllers have the capability to adjust the operating frequency
of the
system to adapt itself and prevent flickering effects under certain
lighting conditions. In addition to that, the lower the frequency used, the less
power is consumed by the
system.
The
system can work at the following settings:
1. LINE –
system operates at the line frequency and is synchronized to
Line frequency (50/60 HZ depending on country of use).
2. 32HZ –
system operates at a frequency of 32 Hz, and is not synchronized
to the line.
3. LINE/2 –
system operates at half the line frequency and is
synchronized to the line frequency (25/30 HZ depending on country of
use).
In order to define the operating frequency of the
system, use the switch
located on the side panel of the controller.