6
5
Cap
Bottle
Hydrogen Generator
Unable to Charge Bottle (LED lights do not light up)
• Unscrew the cap counterclockwise and remove it from the bottle. Gently wash using a sponge
with diluted neutral detergents, rinse thoroughly and air dry.
When attaching the cap after cleaning, make sure the gasket does not come off.
Close cap firmly twisting until it stops. If cap is loose or the gasket is off, this may cause water
leakage so please be careful.
• When the battery is exhausted, the LED lights will not light up (for a few seconds) even if it is
plugged into a power outlet.
• Make sure the USB AC/DC adapter is securely plugged into the power outlet and the USB
power cable is securely plugged into the USB AC/DC adapter.
Precautions for Care
* Do not turn the switch on when citric acid solution is in the bottle.
* When cleaning with citric acid solution, remove the chlorine removal
cartridge.
There is a cleaning mode function to keep the electrodes of the hydrogen water bottle clean and
enhance hydrogen generation.
• Pour water about half of the bottle and press the power switch for over 5 seconds.
The LED lights will turn blue and the cleaning mode begins.
• Cleaning mode stops after 3 minutes.
• After cleaning, discharge the water in the bottle, and conduct normal cleaning of the bottle.
* LED lights stay blue during cleaning.
If cleaning mode has not been used for a long time, mineral deposits may form around the
electrodes so washing the electrodes with citric acid solution is recommended. Pour 100ml or
more of citric acid solution into the bottle and leave for about 10 hours (to make citric acid
solution, dissolve 5 g of citric acid in 100 ml of lukewarm water).
After cleaning, rinse with water several times. By removing deposits that have formed on the
electrodes, the electrodes will be kept clean.
Although dependent on frequency of use, it is recommended that cleaning be done once every
2-3 months.
• When washing the bottle, remove the hydrogen
generator at the bottom of the bottle–refer to diagram
❺
. Gently wash only the inside of the bottle using a
sponge with diluted neutral detergents, rinse
thoroughly and air dry.
* Since the USB port and power switch are not
completely waterproof, make sure that these parts
do not get wet. This may cause electric leakage or
malfunctions.
How to Care for the Product
Hydrogen Gas Inhalation
• Press the power switch 2 times (press longer the
second time, in 3 seconds after the first time)
and hydrogen will be generated for 30 minutes.
The LED lights turn green and after 1 second, the
lights change to rainbow colors and hydrogen
generation starts. Once completed, the buzzer
sounds and the LED lights go off.
* For the hydrogen gas inhalation, use only mineral
water or refined water, DO NOT use tap water.
• Tightly close the inhaler cap to prevent water
leakage, and attach the inhaler cannula to the
inhaler cap.
• Pour mineral water or refined water up to about
90% of the bottle. (Check the water line
indicated in
❾
on the right)
Prepare the inhaler cap and the inhaler
cannula, put the inhaler cap on the bottle.
• Put the inhaler cannula behind ears and wear it
as picture on the right.
9