background image

S405.100 & S406.100 

USER GUIDE

Routine Maintenance | 47

5.3 REPLACING THE INTRAMUSCULAR INJECTION INSERT

1. 

Carefully roll down the skin on the pediatric 
arm about a quarter of the way to reveal the 
upper lateral subcutaneous injection insert. 

1. 

Remove the intramuscular insert at the 
deltoid area of the pediatric arm.

2. 

Replace with a new, unpunctured 
intramuscular insert. 

5.4 REPLACING THE SUBCUTANEOUS INJECTION INSERT

Summary of Contents for S405.100

Page 1: ...sist a certified instructor It is not a substitute for a comprehensive understanding of the subject matter and not intended for clinical decision making User Guide 20 10 02 Gaumard Scientific Company...

Page 2: ......

Page 3: ...3 2 PACKAGE CONTENTS 10 3 3 IDENTIFYING ARTERIAL AND VENOUS TUBING 11 3 4 BLOOD RESERVOIR STAND ASSEMBLY 12 3 5 SYSTEM CONNECTIONS QUICK GUIDE 15 3 6 POWER SUPPLY FOR THE CONTROL BOX 16 4 WORKING WITH...

Page 4: ...CING THE SUBCUTANEOUS INJECTION INSERT 48 5 5 REPLACING THE ARM SKIN 49 5 6 REPLACING THE VEINS 52 6 TROUBLESHOOTING 54 6 1 GENERAL TROUBLESHOOTING 54 7 APPENDIX 55 7 1 REPLACEMENT PARTS LIST 55 7 2 G...

Page 5: ...the Radial artery Brachial artery subcutaneous injection site on the the lateral side of the upper arm an intramuscular injection site in the deltoid area and a section of the humerus 1 2 SPECIFICATIO...

Page 6: ...pate using fingernails as this may tear the skin palpate using the pads of the fingers Operating Temperatures Operating temperature 50 95 F 10 35 C Humidity 5 95 non condensing Storage Store the venou...

Page 7: ...water then drain the vein reservoirs at the end of each day of simulation Doing so will retard the formation of mold and prevent clogging of the system The skin of the training arm can be cleaned wit...

Page 8: ...ation Infusion Bolus Injection Blood draw collection Observe flashback Radial and brachial arterial puncture Cannulation Blood sampling collection Observe flashback IM injection Sub Q injection Humera...

Page 9: ...ulation Infusion Bolus Injection Blood draw collection Observe flashback Radial and brachial arterial puncture Cannulation Blood sampling collection Observe flashback IM injection Humeral IO access an...

Page 10: ...n a bed or clean flat surface 3 2 PACKAGE CONTENTS 1 Pediatric Patient Injection Training Arm 2 Arm Stand Assembly 3 Silicone Stand Cushion installed on Arm Stand 4 Blood dispensing bag 5 Blood Reserv...

Page 11: ...05 100 S406 100 USER GUIDE Initial Setup 11 3 3 IDENTIFYING ARTERIAL AND VENOUS TUBING 1 Pump Inlet Tubing 2 Venous Drain Tubing 3 Vein Inlet Tubing 4 Artery Oulet Tubing 5 Pump Outlet Tubing 1 2 3 4...

Page 12: ...sert both plastic blood stand brackets through the larger holes punched out on the blue metal base 3 Rotate the plastic blood stand brackets so the hollowed out groove is pointing towards the longer l...

Page 13: ...ire frame into the hollowed out grooves on the plastic blood stand brackets NOTE It is helpful to brace your forefinger on the plastic blood stand brackets and use your thumb to push the blood stand w...

Page 14: ...d arterial connection venous connection fill inlet drain outlet waste container NOTE The blood bag will hang from the metal knobs at thetop of the wire frame NOTE This diagram is based upon having the...

Page 15: ...the power supply with power cord 2 Connect the power cord to the power supply 3 Plug the power cable into the control box and plug the other end into a wall outlet NOTE If necessary use one of the int...

Page 16: ...ump outlet tubing It has one end with a white luer lock outlined in red and the other end is a black luer lock The second arterial tube is the artery outlet tubing It has one end with a black luer loc...

Page 17: ...the port it is being connected to 5 Using the second arterial artery outlet tube connect and secure the black luer lock outlined in red to the black port outlined in red on the pediatric arm NOTE Matc...

Page 18: ...twork They will be connected to corresponding ports on the pediartic arm that are also outlined in blue The first venous tube is the vein inlet tubing It has one end with a white luer lock outlined in...

Page 19: ...blue to the corresponding port on the pediatric arm 4 Place the other end of this tube into a waste collection container NOTE Leave the tube unclamped Control Box Connection 1 Get the pump inlet tubin...

Page 20: ...of the blood dispensing bag NOTE It is recommended to connect this end to the bottom left port on the blood dispensing bag NOTE Push the barb connector past its barb so that the bag does not leak when...

Page 21: ...an assist in the mixing of this solution 2 Alternate between adding the Artificial Blood Plus Additive MIx powder and water in the jug Shake between each addition to aid dissolving of the powder NOTE...

Page 22: ...ng smaller batches of the blood concentrate The size and weight of the water bottle also makes it easy to pour into the blood dispensing bag 2 Connect the barb connector end of the tube to the middle...

Page 23: ...he instructions on the artifical blood concetrate bottle to mix with water It is easier to fill the blood dispensing bag when it is taken off the wire frame and filled NOTE The blood dispensing bag ca...

Page 24: ...blood dispensing bag Priming the Pediatric Arm 1 Gather the fill syringe kit and prepared artificial blood concentrate NOTE The artifical blood shown here is already mixed with water 2 Assemble the fi...

Page 25: ...Connect and secure the syringe to the white venous port outlined in blue on the pediatric arm 5 Push the syringe until the venous drain runs with blood and minimal air bubbles 6 Disconnect the syring...

Page 26: ...in the waste collection container 2 Allow the artifical blood to run from the blood dispensing bag through this tube until the tube is completely filled and there are minimal air bubbles 3 Clamp the...

Page 27: ...em Having any of the tubing clamped while turning the system ON to fill the system can increase pressure to the vasculature and potentially damage the control box if the pressure build up is too great...

Page 28: ...nfusion 24 G Intradermal injection 26 G Intramuscular injection 20 23 G Humeral IO 15 mm Procedure Device Size Needle Stick 22 G or smaller Infusion of large amounts of fluid 18 22 G General infusion...

Page 29: ...arm allow it to rest on its stand NOTE The ventral side of the S405 100 pediatric arm present the cephalic and basilic venous networks the median cubital vein and the radial artery for arterial blood...

Page 30: ...ch in effect increases the pressure in the system s vasculature NOTE This will simulate bulging veins and or arteries for blood collection exercises 4 Twist the knob on the squeeze bulb of the pressur...

Page 31: ...The subcutaneous site is for placement only It cannot hold or absorb large amounts of fluid The S406 100 pediatric arm does not have a subcutaneous injection site Locate the Intramuscular Injection Si...

Page 32: ...rate NOTE The pulse rate can be set bewteen 12 180 bpm If a pulse rate of zero is desired turn off the control box 1 On the control box turn the Pulse Strength knob clockwise to increase or counter c...

Page 33: ...e humerus of the pediatric arm using the appropriate medical equipment NOTE Recommended humeral IO needle is 15 mm for both the S405 100 and S406 100 3 Refer to section 5 Routine Maintenance on page 3...

Page 34: ...IGURATION Disconnecting the Pediatric Arm 1 Gather the pediatric arm and the allen key hex 2 Rotate the pediatric arm to see the screw in the upper shoulder 3 Use the allen key hex to loosen the screw...

Page 35: ...t NOTE Do not pull too hard If you do it may rip out the connections 6 Disconnect the tubing by pressing the orange part of the quick connector inward like a button and pulling the tube outward NOTE D...

Page 36: ...connect by simply pushing the hose into the quick connector 2 Reconnect the green tube from the shoulder to the quick connector in the arm that is attached to a green tube Reconnect by simply pushing...

Page 37: ...100 USER GUIDE Working with the Simulator 37 4 Twist the shoulder and arm halves so that they are secure 5 Tighten the screw in the shoulder with the allen hex wrench NOTE The arm is now ready for st...

Page 38: ...diatric Arm Venous Network 1 Disconnect all tubing from the pediatric arm except the venous drain that has the black luer lock connection outlined in blue NOTE Leave the venous drain black luer lock c...

Page 39: ...ge NOTE Do not mix alcohol into the distilled water Flush the veins with pure distilled water 3 Connect and secure the syringe to the white luer lock venous connection outlined in blue on the pediatri...

Page 40: ...ure the syringe back to the white luer lock venous connection outlined in blue on the pediatric arm 7 Push the air through the venous network to purge any remaining fluid out through the drain 8 Dicon...

Page 41: ...lushing the Pediatric Arm Arterial Network 2 Fill the syringe with distilled water NOTE Do not mix alcohol into the distilled water Flush the veins with pure distilled water 3 Connect and secure the s...

Page 42: ...nge with air 6 Reconnect and secure the syringe to the white luer lock arterial port oulined in red on the pediatric arm 7 Push the air through the arterial network to purge any remaining fluid out th...

Page 43: ...Dispensing Bag and Control Box 2 Remove the blood dispensing bag from the wire frame 3 Empty the remaining contents of the blood dispensing bag through the top right port on the bag into a waste colle...

Page 44: ...leaning solution may already run through the tubes by itself 6 Turn ON the control box to clean the remaining tube 7 Allow the system to run until the tubing runs clear with distilled water 8 Disconne...

Page 45: ...nnect it from the pediatric arm NOTE The humerus will have to be replaced after each puncture to prevent leaking when pressure is added to the venous network NOTE Use the pads of your fingers to remov...

Page 46: ...unctured humerus by inserting the new humeral bone into the ports that were revealed 4 Replace the intramuscular insert by sliding the insert into the recess NOTE Push the intramuscular insert into it...

Page 47: ...fully roll down the skin on the pediatric arm about a quarter of the way to reveal the upper lateral subcutaneous injection insert 1 Remove the intramuscular insert at the deltoid area of the pediatri...

Page 48: ...LACING THE ARM SKIN 1 Roll the arm skin down starting at the end closest to the shoulder 2 Lift out the used subcutaneous injection insert and replace it with a new one 3 Hold the subcutaneous injecti...

Page 49: ...to aid in rolling on the new skin 5 Fold the arm skin on itself to put over the hand of the arm NOTE Be careful not to grip the skin with fingernails as this may leave marks or tear the material Plac...

Page 50: ...lide the rest of the skin up the arm NOTE This is the easy part NOTE Line up the the skin opening to fit over the ports on the pediatric arm NOTE Use the pads of your fingers to pinch and pull the ski...

Page 51: ...pulling upwards and popping it off its white connector 3 Use the removed vein to measure out a length of new vein tubing and cut with a pair of scissors NOTE Do not pull too hard on the veins A minima...

Page 52: ...NOTE Slide the new vein past the barb on the white connector until it is fully seated Secure all veins this way so that the system doesn t leak when filled 5 For veins that slip out of their designat...

Page 53: ...outlet the power cable is plugged into is a working one There is no fluid flowing through the vasculature of the arm when the system is turned ON no fluid is exiting the drainage tubings The fluid flo...

Page 54: ...ficial Blood Concentrate Kit Consumable 30081176A CMC Additive Consumable 11090012 Baby Powder Consumable 13082005A S405 100 IV Arm Shoulder Insert Light Consumable 13082032A S405 100 IV Arm Shoulder...

Page 55: ...Reservoir Stand Assembly Replacement Part 14060059 Power Supply Desktop AC DC 12V 5A 60W Replacement Part 30070925B Pediatric AIV Arm Control Box Assembly Replacement Part 13090034D Sealed Bags New IT...

Page 56: ...or to take possession or otherwise dispose of Products for which payment is overdue 4 Product Shipment and Risk of Loss Unless otherwise agreed to in writing by Gaumard all Products will be shipped F...

Page 57: ...ge permit or the like Licenses even if applied for by Gaumard on Customer s beHAL f If any authorization is delayed denied revoked restricted or not renewed Gaumard sHAL l not be liable and Customer i...

Page 58: ...y become due 2 a voluntary or involuntary bankruptcy proceeding is instituted by or against a Party hereto or 3 an appointment of a receiver or assignee for the benefit of creditors occurs on beHAL f...

Page 59: ...to disclose or make available to other parties the Gaumard Software in source code format 2 8Certification Upon thirty 30 days written notice to End User from Gaumard End User sHAL l certify End User...

Page 60: ...as FedEx or c when received if sent by certified or registered mail postage prepaid return receipt requested Any such notice given to a party sHAL l be sent to the addresses on the attached Purchase O...

Page 61: ...d produced by Gaumard This limited warranty does not apply to any products provided along with the Gaumard product that are manufactured by third parties For example third party products such as compu...

Page 62: ...to the simulator for possible troubleshooting as needed Technical Support Email support gaumard com USA 800 882 6655 INT 01 305 971 3790 7 6 GENERAL INFORMATION Sales and Customer Service E mail sale...

Reviews: