2. Overview

2.1 Features

The S117 and S117.250 is a multipurpose simulator with the following features:

Appearance

  

· Anatomically correct landmarks for proper hand placement

  

· Realistic chest cavity

  

· Lungs and ribs 

  

· Lifelike face/head skin for realistic jaw thrust, head tilt / chin lift

Airway

  

· Oral and nasal intubation

  

· Use an ET tube or LMA

  

· Realistic airway with tongue and vocal cords

Artificial Respiration

  

· Visible chest rise with bag valve mask ventilation

  

· Ventilation measured and logged

  

· Tracheostomy care

Circulation

  

· Intramuscular injection sites on deltoids and quadriceps

  

· Intraosseous infusion site

  

· Manual palpable pulses

Systemic

  

· Stoma care 

  

· Gastrostomy 

  

· Catheterization

Venous Access

  

· Intravenous training arm and hand 

  

· Femoral venous access 

Summary of Contents for S117

Page 1: ...7 1 Gaumard Scientific Company 2018 All Rights Reserved www Gaumard com S117 S117 250 is an interactive educational system developed to assist a certified instructor It is not a substitute for a comp...

Page 2: ...ma Care 8 2 Overview 9 2 1 Features 9 Appearance 9 Airway 9 Artificial Respiration 9 Circulation 9 Systemic 9 Venous Access 9 CPR Options 10 2 2 Terminology 10 Facilitator 10 Provider 10 2 3 Packing C...

Page 3: ...rcises 31 4 5 Hospital Care Capabilities 32 Intramuscular Injection Sites 32 Bandaging 32 Eyes Ophthalmologic Exercises 32 4 6 Chest Decompression and Drainage Optional 32 4 7 Heart and Lung Sounds Op...

Page 4: ...us 47 Pressure Sensor 50 Calibration 51 8 3 Circulation 52 Chest Compressions 52 9 Appendix 54 9 1 Spare Parts List 54 9 2 Troubleshooting 55 Communication Power Issues 55 Miscellaneous Issues 55 10 W...

Page 5: ...nship Electronic transmission is warranted to be free from defects at the moment of transmission Your sole and exclusive remedy and Gaumard s sole liability is to replace the defective media or to rep...

Page 6: ...this or any other Gaumard product in newsprint Marks made with ballpoint pens ink or marker cannot be removed Replacement parts are available from Gaumard Scientific or from your Distributor Operating...

Page 7: ...oof but not water proof Do not submerge or allow water to enter the interior of the simulator IV Arm Only use Gaumard s provided simulated blood Any other simulated blood containing sugar or any addit...

Page 8: ...omas as indentations will form on the pressure points The stomas may return to the normal shape after the pressure is relieved Place baby powder on the stoma surface to reduce tackiness This can be re...

Page 9: ...thrust head tilt chin lift Airway Oral and nasal intubation Use an ET tube or LMA Realistic airway with tongue and vocal cords Artificial Respiration Visible chest rise with bag valve mask ventilation...

Page 10: ...ff member Provider A person participating in the simulation as a healthcare provider 2 3 Packing Checklist Pulse Line with squeeze bulb Male genitalia installed Spare right arm skin 4 Stoppers Port Fi...

Page 11: ...ING To avoid damage to the simulator please store and ship it in the clear poly bag provided OMNI Wired Connection Setup Optional Follow the steps below to connect S117 to OMNI 1 Connect the power sup...

Page 12: ...r wirelessly Follow the steps below to connect to OMNI 2 4 Connect the power supply to the simulator Always operate the simulator with the power supply connected 5 Turn on OMNI 2 by pressing and holdi...

Page 13: ...e Tutorial at any time by selecting HOME Please complete the tutorial once or it will continue to appear at start up After the tutorial OMNI 2 will automatically proceed to the Favorites page and esta...

Page 14: ...an be intubated orally or nasally The simulators s airway can be intubated through the left nasal opening trachea and mouth using LMA or endotracheal tubes WARNING Manually lubricate the ET tube and n...

Page 15: ...Fr catheter Tilting the head forward obstructs the airway 4 2 Artificial Respiration Ventilation Visualize realistic chest rise with BVM or via an endotracheal tube with manual ventilation WARNING Do...

Page 16: ...ructions for Use 1 Lubricate the device with mineral oil 2 Insert the tracheaostomy tube and pierce the trachea tape Trachea Repair 1 Lift the chest skin 2 Lift until you expose the trachea 3 Remove t...

Page 17: ...irculation Compression The chest cavity contains realistic landmarks for correct hand placement during CPR Palpable Pulses The simulator is equipped with pulses generated by a squeeze bulb located on...

Page 18: ...rcises Procedure Recommended Device Size IV Access 22 Gauge The training arm features An intramuscular injection site in the deltoid area Simulated cephalic basilic antecubital radial and ulnar veins...

Page 19: ...17 19 1 Place the end of the drainage hose into a container 2 Open the clamp 3 Fill the syringe with fluid and connect it to Tube 1 4 Allow fluid to flow into the drainage container 5 Close the clamp...

Page 20: ...ing the Skin WARNING Vein tubing contains latex which may cause allergic reactions Users allergic or sensitive to latex should avoid contact After a simulation is complete 1 Open the clamp of Tube 2 2...

Page 21: ...e 3 Apply some mineral oil to the arm to ease the movement of the skin The skin of the training arm can be cleaned with a mild detergent or soap and water After drying the arm lightly dust it with bab...

Page 22: ...ollow steps below Right Leg Filling Left Leg Drainage 1 Place Left Leg hose in a drainage container 2 Leave drainage clamp open 3 Fill a syringe with fluid and connect the syringe to the Right Leg hos...

Page 23: ...ation is complete 1 Place a drainage tube in the Left Leg into a container and open the clamp 2 Fill the syringe with a solution of alcohol and water 30 70 and connect it to Tube 1 3 Push in the fluid...

Page 24: ...is no fluid in the bone 2 Remove the tibia cover 3 Pull the tibia bone out 4 Replace tibia bone and push it down in place 5 Re attach tibia cover Femoral Access Supply simulated blood into the right f...

Page 25: ...uid system as the IO access 4 4 Systemic Gastrostomy Port The simulator includes a gastrostomy opening to drain the stomach fluids that were introduced through the esophagus Tank Capacity Stomach 100...

Page 26: ...he syringe with a solution of 70 30 water and alcohol 6 Insert the solution into the stomach reservoir 7 Push in the fluid 8 Allow for the rest of the contents to drain from the reservoir Ostomy Care...

Page 27: ...connected to the same reservoir Tank Capacity Right Ostomies 50 mL Add fluids to the ostomy on the left of the simulator and practice enema procedures Tank Capacity Rectum 250 mL Filling the Internal...

Page 28: ...dapter 5 Use the provided stoppers to prevent any spilling Draining the Internal Reservoirs 1 Insert the filling kit adapter to the ostomy port 2 Suction fluid from the reservoir with the syringe 3 Th...

Page 29: ...eterize the simulator with a size 8 Fr catheter The simulator is supplied with male genitalia Tank Capacity Bladder 125 mL Procedure Device Size Urinary Catheterization 8 Fr Removing the Male Genitali...

Page 30: ...dapter to the suprapubic port 2 Fill the syringe with fluid 3 Insert the adapter into the suprapubic port 4 Fill the reservoir 5 Leave the adapter and syringe inside the filling port to keep the reser...

Page 31: ...ing to the side Use a lubricated anal nozzle of small diameter to perform the procedure Nasogastric and Orogastric Exercises Nasal and oral openings are connected to the stomach reservoir Insert an ap...

Page 32: ...resistant to water oil and liniments Eyes Ophthalmologic Exercises The head has eyes that open and close permitting the following exercises Administration of orbital medicines into the conjunctival sa...

Page 33: ...structions for Use 1 Lift the chest skin of the simulator to reveal the chest cavity 2 Remove the regular ribcage 3 Place the decompression and drain ribcage in position 4 Connect the squeeze bulb to...

Page 34: ...p a chest drainage exercise follow the instructions below 1 Open the clamp of the drainage hose and place the end of the hose into a container 2 Connect a filled syringe to the filling tube 3 Allow fl...

Page 35: ...m is composed of a Virtual Stethoscope and sensors located beneath the skin in a total of 13 locations 9 on the front and 4 on the back Assembly 1 Unscrew the stethoscope bell 2 Gently pull on the rem...

Page 36: ...rso Instructions for Use 1 Push and hold the power button to turn on and off The green light will appear when it is on 2 Press the sound button to select the desired sound set as shown in the VS Sound...

Page 37: ...7 37 5 Using OMNI 2 S117 250 OMNI 2 applies for only to the S117 250 PK or OMNI2 U 5 1 Main Screen OMNI 2 opens at the Favorites Page upon start up Changing a Vital Sign In order to change one of thes...

Page 38: ...st the value utilizing the icons or the slider dot 3 Select APPLY NOW 5 2 CPR OMNI 2 features a CPR performance evaluator and trainer WARNING Do not perform mouth to mouth ventilation since the simula...

Page 39: ...on about the CPR monitoring and reporting refer to the OMNI 2 User Guide Compressions Calibration It is recommended to calibrate the compressions before using the feature for the first time 1 Tap the...

Page 40: ...S117 S117 250 User Manual 40 Using OMNI 2 S117 250 2 Select Calibration 3 Press Compression from the calibration window 4 Tap START and perform 5 compressions 5 After the 5 compressions tap SAVE...

Page 41: ...to activate this feature The simulator must be connected to the OMNI 2 tablet in order to establish a connection to the Virtual Monitor 1 Connect the provided router to the wall 2 Tap the gear on the...

Page 42: ...Follow steps 9 10 if the activation code was not previously entered 9 Verify that the serial number corresponds to the manikin 10 Input a valid activation code The activation code is case sensitive No...

Page 43: ...s software 15 Tap the V on the top left and then select Comm Setup 16 Verify that the IP address in the Wireless Communication Setup matches the Omni IP and Omni Port noted before 17 Select Connect Th...

Page 44: ...e notification below appeared OMNI 2 has to be paired to a simulator to establish a connection with the simulator 1 Connect the power supply to the simulator 2 Tap the Gear on the upper right corner o...

Page 45: ...o return to the main screen 7 Tap the gear on the upper right and select Connect to Simulator 8 Select the simulator you wish to connect to and tap Connect and Save as Default The name of the simulato...

Page 46: ...rds and will contaminate the airway 8 1 eCPR eCPR is an application that enables monitoring and logging of com pressions and ventilations performed in real time by the user on a PC This software aims...

Page 47: ...d on the right side of the controller Each menu has additional submenus or toggle selections Use the submenus to decrease ncrease accept or cancel values Navigation Menus MODE This submenu is for the...

Page 48: ...he number of com pressions or ventilations per minute The default is 100 CPM 1 Select CMP RATE button 2 Adjust the rate using the and buttons 3 Press OK to save the changes The compression rate limit...

Page 49: ...lue for OMNI s backlight timer is 10 minutes After 10 minutes the backlight will turn off 1 Press SCREEN to access the backlight settings 2 Use the and buttons to adjust the brightness and time of the...

Page 50: ...altitudes greater than 1000 ft to avoid inaccurate compression and ventilation readings 1 Navigate to the calibration menu 2 Select either C CAL or V CAL 3 Press the RESET button 4 Perform the calibr...

Page 51: ...entilation Calibration 1 Press the button that reads CALIB 2 Select V CAL 3 Press START 4 When OMNI is ready to calibrate it will dis play VENTILATE Follow the cues on the screen to perform one ventil...

Page 52: ...ional 6 Press SAVE to store the calibration 8 3 Circulation Chest Compressions It is recommended to calibrate the compressions before performing compressions Compression Calibration 1 Press the button...

Page 53: ...ode Blue Optional 53 4 When OMNI is ready to calibrate it will display COMPRESS Follow the cues on the screen to perform one compress at a time until finished 5 Perform a total of 5 ventilations 6 Pre...

Page 54: ...es and replacement parts and their prices Item Type Part Number Arm Skin Consumable S117 813 L M D IO Tibial Bones Consumable S117 835 Artificial Blood Concentrate Consumable S117 812 IO Skin and Bone...

Page 55: ...paired Disconnect the simulator from the power supply turn off bluetooth on OMNI 2 tablet Plug the simulator and turn on bluetooth Power supply is not connected to simulator Ensure that the power sup...

Page 56: ...al rights This limited warranty applies only to the first purchaser of the product and is not transferable Any subsequent purchasers or users of the product acquire the product as is and this limited...

Page 57: ...ss to the simulator for possible troubleshooting as needed Technical Support Email support gaumard com USA 800 882 6655 INT 01 305 971 3790 11 2 General Information Sales and Customer Service E mail s...

Page 58: ...atbelt Susie Krash Kids Premie UNI Omni Omni 2 SmartSkin are trademarks of Gaumard Scientific Company Always dispose of this product and its components in compliance with local laws and regulations ww...