6. APPENDIX
6.1 TROUBLESHOOTING
Part ID
Name
Description
13082074A
Scrotum (L)
Set of 2, Light skin toned
13082075A
Scrotum (M)
Set of 2, Medium skin toned
13082076A
Scrotum (D)
Set of 2, Dark skin toned
30081201A
Testes Kit
Includes (1) Cancerous Testis 1, (1) Cancerous Testis
2, and (2) Normal Testes
30022436A
Rotational Prostates Assembly
(1) replacement Rotational Prostates Assembly
30031739A
Vas Deferens Assembly
(1) Length of Vas Deferens tubing
30022433A
S230.200 Colon Assembly
(1) Colon Assembly replacement
30022424A
S230.200 Skin Assembly, Light
(1) Light Skin Toned Simulator Skin replacment
30022425A
S230.200 Skin Assembly, Medium
(1) Medium Skin Toned Simulator Skin replacment
30022426A
S230.200 Skin Assembly, Dark
(1) Dark Skin Toned Simulator Skin replacment
30081246A
Fill and Drain Kit
(1) Syringe, Fill Connector, Drainage Hose, and
Squeeze Pump Assembly
GU.156
Talcum Powder
GU.181
Mineral Oil
Symptom
Possible Cause
Solution
Cannot palpate or
"feel" the prostates
when performing
digital prostate exam.
The rotational prostate
disc is misaligned.
Remove the back panel of the simulator
and tighten the black nut on the
rotational prostate disc to ensure
that the disc is properly aligned.
Not enough force was applied
when pressing the pelvic button
to rotate the prostate disc.
Perform one additional, full force button
press to rotate the disc properly.
6.2 PARTS LIST
S230.200 ADVANCED ZACK™
|
USER GUIDE
Appendix | 27