GT510 ATF System Service Centre
7
.3 Power cables connection
Connect the power cables clamps of the unit to the two poles of the vehicle battery.
1.4 Check-up
1) Start the engine, and ensure that there is no leakage in pipeline.
2) Open the ATM-300 power switch and ensure that the power of the unit is normal.
2. Filling liquid
2.1 Filling detergent
When you are ready to perform the circulating cleaning for auto transmission, fill proper
detergent from the fill port under the circumstance that there is no new fluid.
2.2 Adding new fluid
When you are ready to perform the exchange operation, fill new fluid to be replaced from
the fill port.
3. ATF exchange
1) Fill the fluid into the tank of the unit.
2) Start the vehicle to make the transmission to normal fluid temperature
3) Setting the exchange fluid amount and run the Exchange function.
4) Setting the detergent amount.
5) Setting if Isothermal exchange. If set to be, the equipment will preheat the new fluid.
6) When the exchange is completed, the unit will alarm and it enters the circulating
cleaning state.
7) If there is no used fluid into the old tank of the unit keeping 40 seconds, the unit will
alarm and please check the pipeline.
8) Check the fluid level inside transmission. If the level is not enough, supplying fluid is
required. Refer to the section of Adjust fluid level for the detailed operation.
9) Disconnect the unit and resume the hoses of the transmission.
10) Start the engine and check if there is fluid leakage in the auto pipeline.
Note:
Switch each gear when exchanging. The time of each shift should stay about 1
minute, which depends on actual situation. When the auto is running at
high-speed gear and accelerate the speed to more than 60 km/h, the ATF inside
fuel control pipeline can be exchanged.
To ensure the exchange quality, the quantity of new fluid inside the unit should
be 2L~3L more than that of the fluid required by auto transmission.
Do not add new fluid from the new tank during the running period of exchange.
Otherwise, the operation will result in inequality amount. If there must be added
the new fluid, fill after this exchange is completed!