![GATEXPERT GK-E Series User Manual Download Page 25](http://html1.mh-extra.com/html/gatexpert/gk-e-series/gk-e-series_user-manual_3757021025.webp)
Instructions for GK-E SERIES
www.gatexpertstore.com
23
Note: Only need to pair “button A”, the pairing of the remote control is finished
meanwhile.
b、
Remote control delete
:
Press and hold AN button on the receiver, LED light will be on, release the button until
the LED light is off, all paired remote controls are deleted.
Note:Recommended to operate the remote control deletion first and re-p
air the remote before you use the operator for security consideration.
Use of hand-pulled chain
When you need to manually open or close the industrial door, then hand-pulled chain
would be required.
Before pulling the chain, please fully pull the red handle A in the hand-pulled chain
mechanism to make it engage with the main machine. The protection switch inside the
hand-pulled chain mechanism will automatically cut off the power supply. At this time,
the chain can be pulled.
The chain should be pulled continuously and evenly to avoid damage to the
hand-pulled chain mechanism.
When you need to electrically open or close the industrial door, please fully pull the
green handle B in the hand-pulled mechanism first to make it disengage from the
main machine, and the protection switch in the hand- pulled mechanism will be reset
to make the industrial door operator return to its normal electric operation. Please fix
the hand-pulled chain on the wall properly when it’s not in use.
Note: 1. After the chain is used, if digital displays E--06, the door cannot be
opened or closed electrically, because protection switch in the hand-pulled
chain mechanism has not been automatically reset. To fully pull the green
handle in the hand-pulled chain mechanism to separate it from the main