![GATEXPERT GK-E Series User Manual Download Page 20](http://html1.mh-extra.com/html/gatexpert/gk-e-series/gk-e-series_user-manual_3757021020.webp)
Instructions for GK-E SERIES
www.gatexpertstore.com
18
Input Status:
Parameters Setting
Input Status
No.
Instruction
1
Stop
2
Open
3
Close
4
Photo Sensor
5
Air Bag
6
Loop Detector
7
Partial Opening
8
Single Cycle
9
Interlock
No.
Parameters
Value Range
Default
P1
P1-F1
Electronic limit switch setting
P1-F2
Pre-stop before arriving at the open
limit switch position
0-200
50
P1-F3
Pre-stop before arriving at the
closed limit switch position
0-200
60
P1-F4
Delay time for Auto-close
0-120 sec.
10
P1-F5
Height of partial opening
0-100%
50
P1-F6
Inch move for opening
0=Continuously
move
;
1=Inch move
0
P1-F7
Inch move for closing
0=Continuously
move
;
1=Inch move
0
P1-F8
Restore to factory setting of P1
0=No
;
1=Yes
0
P2
P2-F1
Stop of external three buttons
switch
0=NO
;
1=NC
0
P2-F2
Partial opening
0=NO
;
1=NC
0
P2-F3
Single cycle
0=NO
;
1=NC
0
P2-F4
Photo sensor
0=NO
;
1=NC
0
P2-F5
Loop detector
0=NO
;
1=NC
0
P2-F6
Airbag
0=NO
;
1=NC
;
2=pulse
0
P2-F7
Mechanical limit switch
0=NO
;
1=NC
1