background image

PY800AC/PY1400AC SLIDING GATE OPERATOR

12

1

2

3

4

Button 1

Button 2

Button 3

Button 4

Fig.12 Remote transmitter

Adding extra remote controls (Learn): Remove the cover, press the

learn button ‘AN1’ (Fig.8), then the ‘LED2’ (Fig.8) will be on and

turn off, then press the remote control button which you want to use,

the ‘LED2’ will turn on about 2 seconds and then turn off again. The

learning process is finished.

Up to 25 remote controls may be used.

Erase remote controls: To erase all existing remote controls, press

and hold learn button ‘AN1’, the ‘LED2’ turns on, release the button

once the ‘LED2’ turns off. This indicates that all the remote controls

have been erased completely.

Note

Note

Note

Note

: Press the ‘OPEN’ button of external button switch or remote

control button which has been learned, the gate will open, the motor

rotates clockwise, and the ‘LED2’ is turns on. The output voltage

between ‘D1 and D2’ (terminal X3) is AC220V/110V, the voltage

between ‘V’ and ‘U’ is AC220V/110V. Press ‘STOP’ button or the

same remote control button, the gate stops running. And the ‘LED2’ is

turns off. Then press ‘CLOSE’ button or the same remote control

button again, the gate will close, the motor rotates anticlockwise, and

the ‘LED2’ is turns on. The output voltage between ‘D1 and D2’

(terminal X3) is AC220V/110V; the voltage between ‘V’ and ‘W’ is

AC220V/110V. Press the ‘STOP’ button or the same remote control

 

Summary of Contents for PY800AC

Page 1: ...Sliding Gate Operator User s Manual PY800AC PY1400AC PY800AC PY1400AC PY800AC PY1400AC PY800AC PY1400AC...

Page 2: ...emergency emergency emergency purposes purposes purposes purposes 2 2 2 2 Important Important Important Important safety safety safety safety information information information information Carefully...

Page 3: ...0AC will handle gate weighting up to 800kg 1400 kg and up to 14m 20m if the proper installation procedures have been followed The PY800AC PY1400AC gate operator operates by forcing a drive rack by a d...

Page 4: ...o maintain proper stability The concrete pad should be approximately 450mm x 300mm x 200mm deep in order to providing for adequate weight and structure to insure proper stable installation Anchors see...

Page 5: ...package with rack on the rack element Lay the first piece of rack on the gear and weld the first nut on the gate Move the gate manually checking if the rack is resting on the gear and weld the second...

Page 6: ...ate Release the gear with the key and push the sliding gate manually to pre determine the position fix the block to the rack and lock the gear by push up the release bar Moving the gate electrically a...

Page 7: ...h the sliding gate manually to pre determine the position fix the block to the rack and lock the gear by push up the release bar Moving the gate electrically adjust the block to the proper position un...

Page 8: ...PY800AC PY1400AC SLIDING GATE OPERATOR 7 Gear Sliding gate Rack Limit block Magnetic Magnetic limit Fig 5 Spring limit Magnetic limit Fig 6...

Page 9: ...e supplied key in the lock Turn the key and pull down the release bar about 90 to release the gear Note Do not exceed 90 be careful not to use too much force otherwise the release bar will be damaged...

Page 10: ...es notes notes of of of of control control control control board board board board a Power Input X1 E Earth L Live N Neutral PY800AC PY1400AC AC220V PY800ACU PY1400ACU AC110V b Caution light connect c...

Page 11: ...e lead of your keypad to CLS of terminal X4 and the other to the COM The keypad will function in single channel mode the DIP switch 1 should be turn to OFF For three button switch installation use the...

Page 12: ...te control The remote control works in a single channel mode It has four buttons See Fig 12 Remote transmitter only one type The function of button 1 button 2 button3 and button 4 are the same With ea...

Page 13: ...turns off This indicates that all the remote controls have been erased completely Note Note Note Note Press the OPEN button of external button switch or remote control button which has been learned th...

Page 14: ...ce device device device responds responds responds responds to to to to your your your your requested requested requested requested function function function function correctly correctly correctly co...

Page 15: ...cell photocell photocell If infrared beam is interrupted during closing the gate will reverse and go open immediately This feature will not function if the gate is in fully opened and closed positions...

Page 16: ...en fails to close 1 Infrared beam is obstructed 2 Infrared photocell function is enable but the photocell has not been installed 1 Remove obstructions 2 Make sure the infrared photocell function is di...

Page 17: ...PY800AC PY1400AC SLIDING GATE OPERATOR 16 No Item Quantity 1 PY800AC PY1400AC sliding gate operator 1 2 Transmitter 2 3 Release key 2 4 User s manual 1...

Page 18: ...TLINE 1 Products introduction 1 2 Important safety precautions 1 3 Main technical parameters 1 4 Mechanical Installation 2 5 Adjustment 5 6 Wire Connecting 9 7 Turning and operation 11 8 Programming P...

Reviews: