ALEXA 35 Housing Setup
Page 18
Cable Connections
Prior to closing the housing shell, the following cable connections must be made:
✓
GPIO / Record.
The 4-way GPIO cable connects the GPIO box to the ALEXA 35
camera. It also connects to the housing's run stop switch. See cable diagram
below for details.
✓
External Monitor.
At this stage, connect the External Monitor BNC connector to
SDI 1 port on ALEXA 35 camera. Also mate the External Monitor power to the
battery D-Tap (or P-Tap) with supplied D-Tap adapter.
✓
Surface SDI.
Optionally connect surface SDI cable to SDI 2 port on ALEXA 35
camera.
✓
Other.
Optionally you may have other cable connections for surface camera
control, lens control, etc. These are special circumstances, contact Gates for
details.
LBUS.
Mate this connector with the
LBUS port on ALEXA 35 camera,
located on the camera front, right side.
NOTE: It may be necessary to slide out
the camera slightly to access this port.
GPIO.
Mate with GPIO box OUT.
Run / Stop.
Mate this connector
with RS port on ALEXA 35 camera,
located on camera rear.
Record Trigger.
This BNC-type connector will
mate with the record trigger connector on the
housing. Upper right, inside shell.
GPIO / Record 4-way
Cable