background image

 
Safe guard (Infrared device or Photocell) 

It is recommended that the installer purchase and install infrared photocells for additional 
safety.  Photocells work by inhibiting the movement of the gate if the beam is broken.  Infrared 
safety devices may be required by law in some areas.  If the  infrared beam is broken during 
closing, the  gates will reverse and open immediately. During opening, the beeper will ring. 
Infrared photocells come in active and passive varieties.  Active photocells require power on 
both sides of the driveway, passive photocells employ a reflector plate so that power is only 
required on one side of the driveway.  Most photocells will provide  DC power input wires + 
and -, and normally closed switch wires.  To install the photocell, attach the DC power + wire 
to terminal 12 on jack JX3, and the common, ground or  – DC wire to 0 on jack JX3.  Attach 
the normally closed wire to IR and the common normally closed wire to 0.  In most cases 
these signal wires are not polarized so they can be interchanged without issue.  Consult your 
manufacturer’s documentation for details. See Figure 4 for a diagram of external interface 
connections.   The infrared device can be obtained through your dealer. To find a dealer, go 
to www.gatekeeperltd.com/dealers 

 
 

Maintenance  

Every six months check the following items for proper operation of the unit: 

l

 

Check the chain lubricant and add 1# grease regularly. 

l

 

Lubricate shafts and sprockets. 

l

 

Keep opener clean at all times.  Check inside cover for insects. 

l

 

Check and tighten anchors bolts. 

l

 

The operator can be  powered by battery  in case of power failure.  It still can provide 
enough power for operating 10 cycles after power disruption. Operating should be less 
than 20 cycles a day. Please switch off the battery if no power is available for more than 
5 days (remove the plastic cover, Turn the switch on top of the operator to the off 
position).  Failure to comply with the above instructions may damage the battery or 
shorten its life. 

l

 

We recommend you put some grease in the keyhole to avoid rusting, also regularly 
grease the wheels and axles if the gate was jammed or cannot be moved smoothly. 
Occasionally inspect the chain to ensure that it is well lubricated, and oil the chain as 
necessary. 

 
 
 

 
 

Summary of Contents for SKC-500DC

Page 1: ...SKC 500DC SLIDING GATE OPENER OWNER S MANUAL ...

Page 2: ...ns 4 Necessary Tools 5 Site Preparation 6 Mechanical Installation 7 Electrical Installation 8 Operation 9 Trouble Shooting 10 Warranty Gatekeeper Ltd P O Box 752 Laceys Spring AL 35754 http www gatekeeperltd com 2005 2007 GatekeeperLtd All Rights Reserved ...

Page 3: ...hrough the gate To Avoid electric shock unplug unit before opening case Make sure the battery inside the operator is charged fully before using Before installation the clutch should be unlocked The auto reverse function must be checked during installation to ensure that the gate can auto reverse in the event of obstruction and it should be inspected regularly The automatic gate opener must be grou...

Page 4: ...occur We do not accept responsibility for damage or injury resulting from installing of this operator ...

Page 5: ... obstruction on closing and stop when it encounters an obstruction on opening as required by UL 325 safety standards Manual key release design for emergency purposes Self locking at any position Battery Backup for loss of power conditions Supports Keypad interface and Magnetic Loop Detectors simultaneously Specifications Transformer Output 16V AC 30 VA Motor Input 12V DC 100W Output Torque Max 7NM...

Page 6: ... least a 10A service Make sure your electrician takes into account the voltage drop involved in running many feet of wire to your installation location If an insufficient gauge of wire is used there will be insufficient power at the site to operatethe opener If you plan to use solar panels to power your gate verify that you have sufficient solar power to charge the battery and provide power for th...

Page 7: ...e pad should be approximately 24 600mm x 12 300mm x 18 460mm deep in order to provide for adequate operation The pad should be 3 70mm above finish grade Be sure to locate the pad so that it will not interfere with the gate In locations where ground freeze is possible extend the pad below the frost line Once the gate is mounted adequately electrical power is available and the concrete pad is poured...

Page 8: ...he cover and insert the manual release key and turn counter clockwise to disengage the clutch Remove the elastic band from the shaft and line up the key on the shaft with the sprocket at the chain box Insert the sprocket from the chain box into the operator shaft Place the operator on top of the base and use 4 5 8 15mm socket head cap screws to mount the chain box in to the base Opener Mount the g...

Page 9: ... shown Spring washer µ 8 Plain washer µ 8 L bracket Square bolt Nut M8 Chain bolt Master link Nut M6 Spring washer µ 6 Plain washer µ 6 Gate Square frame If the gate is of round frame style use theround bolts shown Round bolt L bracket Plain washer 8 Spring washer 8 Nut M8 Chain bolt Master link Nut M6 Spring washer 6 Plain washer 6 Gate Round frame ...

Page 10: ...olts at either end See illustration below Master link Chain bolt Chain Electrical Power The control box should be equipped with a single phase breaker 10A Make sure that the power is OFF before making any electrical connections Remove the cover of the control box perform the wiring and replace the cover again See Fig 3 and wiring notes for control board Connect the supplied transformer to the cont...

Page 11: ...e controls press and hold the learn button for about 15 seconds until the LED2 turns off l Verify open direction If the gate does not move in the desired direction then you will need to reverse the motor operating direction You can do this by exchanging wires D and D OP and CL then insert the wire connector terminal block l Set auto close function This feature can be selected to make the gate stay...

Page 12: ...at you have set the gate will close automatically l Cancel width auto close function of pedestrian mode Cancel width and auto close function of pedestrian mode factory preset Make the first switch of SW DIP switch to ON position down press button 4 to open the gate see Verify open direction section Wait for more than 15 sec Then press the same button to stop the gate wait until the gate close auto...

Page 13: ...ntrol JX2 DI Keypad signal input 12 0 Power supply output DC12V GND IR Infrared photocell input JX3 BI Open signal input JX4 Z Z Alarm lamp DC12V OP CO CL Limit switch open limit common close limit JX5 D D Motor 1 It is used to adjust the auto close time andpedestrian mode 2 No connection 3 No connection SW DIP switch 4 It is used for open and close limit adjustments LED1 Battery charge i ndicator...

Page 14: ...cam clicks the gate can move about 10cm Repeat this step until the gate is less than 10cm from the closed position Also the gate can be manually closed once released which will allow the movement of the gate closer to the fully closed position Adjust limit cam until limit switch is activated Open the gate until the closed limit has been cleared and re close the gate to check that the closed positi...

Page 15: ...er clockwise to disengage the clutch l Open and close the gate manually Safety Auto Reverse Obstruction Sensor The Obstruction Sensor continuously monitors the gate movement for any obstructions If any obstructions are detected when the gate is closing the gate will stop and reverse back to the open position If any obstructions are detected when opening the gate will stop The factory setting is se...

Page 16: ... single channel mode just likethe RF remote If the gate is closed then activating the keypad will open the gate if the gate is open then activating the keypad will close the gate if the gate is moving then activating the keypad will stop the gate If your keypad requires DC power then you can use the 12 or 5 terminals and the 0 terminal for ground as required by your device See Figure 4 for a diagr...

Page 17: ... issue Consult your manufacturer s documentation for details See Figure 4 for a diagram of external interface connections The infrared device can be obtained through your dealer To find a dealer go to www gatekeeperltd com dealers Maintenance Every six months check the following items for proper operation of the unit l Check the chain lubricant and add 1 grease regularly l Lubricate shafts and spr...

Page 18: ...section The limit switch wire connector terminal block becomes loose Check the limit switch mode see table 1 Dip switch Connecting wires or terminal blocks are too loose Check the connecting wires and terminal blocks The electric component on the control board such as Q2 Q91 or Q92 may be damaged Replace the electric component Q2 Q91 or Q92 BTA16 600 or replace the board The gate will not open or ...

Page 19: ...ed Gatekeeper Ltd specifically disclaims any and all implied warranties of merchantability or fitness for a particular purpose It is the purchaser s sole and exclusive responsibility to determine whether or not the equipment will be suitable for a particular purpose In no event shall Gatekeeper Ltd be held liable for direct indirect incidental special or consequential damages or loss of profits wh...

Page 20: ......

Page 21: ...rltd com For updated versions of the manual see http www gatekeeperltd com For Additional Remotes Infrared Photo Cells or Parts please contact your dealer To locate a dealer please visit us at www gatekeeperltd com dealers 2005 2007 GatekeeperLtd All Rights Reserved ...

Reviews: