ASTER Troubleshooting
49
Under Voltage Protection 3
(UVP3)
Protection against over-discharge of the battery. Battery protection
was activated immediately after connecting the battery.
What happened:
1.
Number of cells is different than their number set in GCS
2.
The battery is discharged
What to do:
1.
Set the same number of cells in GCS as in the battery
2. Charge the battery
Motor Disc
(MOTOR DISC)
ASTER did not detect the motor.
What happened:
1.
Motor is not connected
2. Brushes are worn out