Wall-mount type of Air Quality Detector 

Model: GTF300-AQ and GTF300-VOC

 

GASTECH is a professional manufacturer in various gas detectors, carbon monoxide detector, carbon dioxide detector, 
oxygen detector, odor detector, VOC detector, hydrogen sulfide detector and carbon monoxide detector. Welcome tour 
our website 

www.gastech.com.tw 

Environment and Application

 

CIAQ of GTF300-AQ/VOC

 

Fresh air and/or Zero air 

Living room

 

1 - 8

 

Super market, Convenient store 

10 - 20 

Office

 

5 - 20

 

Road side or Bus stop of downtown 

10 - 30 

Public lavatory

 

10 - 40

 

Packing lot or Tunnel of automobile 

10 - 40 

Hospital or Sickroom

 

15 - 25

 

Smoking room of airport 

30 - 90 

Temple

 

30 - 50

 

Fart (close detecting) 

50 - 100 

Smelling breath

 

(Around blow 5 sec continuously)

 

20 - 35

 

Opening sewage 

20 - 40 

In above table except zero air CIAQ is absolutely "1", the other index may be different with user actual detecting, but the higher 

CIAQ means the more pollutant or hydrocarbon compounds exist. 

*Remark: This is a preliminary table, please tour GASTECH website 

www.portadetector.com

 to get the newest update information. 

 

5.1 Odor detecting 

The smell and sense of human is difficult to define, some of scent sense good but some persons might not accept the 
smell. Although everybody has various different sense of smell that cannot define. Anyway, the smell depends on the 
concentration of hydrocarbon compounds in the air. 

 

5.2 Smoke detecting 

GTF300-AQ/VOC is very sensitive of hydrogen, which generated from smoking or incomplete combustion. Therefore, 
GTF300-AQ/VOC is suitable for air-conditioner management and non-smoking surveillance. Besides, 
GTF300-AQ/VOC fire detective performance is superior to normal smoking detector. LPG and LNG gases leakage 
detection GTF300-AQ/VOC is very sensitive and suitable to detect leakage of Natural Gas (Methane / City Gas) and 
LPG (Propone). 
 

5.3 Environmental index 

CIAQ is objective index of environmental either living in most application. Due to smell and sense of human is 
difficult to define but GTF300-AQ/VOC is non-subjective instrument that makes comparison and evaluation of 
environmental. 

 

5.4 Air-conditioner management and air cleaner 

There are various factors such as smoking, odor of rotten food, using volatile solvent, using liquid eraser, bad 
ventilating and so on, cause polluted air and high CIAQ. In order to improve air quality, we may use air cleaner. But 
nobody knows what the air cleaner performance is? GTF300-AQ/VOC will help user to know the air quality and air 
cleaner is effect or not. 

Summary of Contents for GTF300-AQ

Page 1: ...ad the Security Notifications in detail firstly 2 The gas detector might install on wall or steel plate please refer following drawing to make marking then drill the holes Do not use the gas detector as a drilling template to avoid fault 3 Due to the space is very small that is impossible to use wrench Therefore to use female expansion bolts on the wall or tap female screws on the steel plate and ...

Page 2: ...te www gastech com tw 2 4 Analog output A recommend fuse is 0 2 A in the above 5 Relay output A recommend fuse is 0 2 A the diode could be 1N4002 or 1N4004 in the above 6 In order to meet waterproof the wiring material and parts should be met the requirement also 7 The wiring size is not less 0 5 mm 2 or 20 AWG In the case of long distance wiring to apply bigger size or 30 VDC power is better 8 Th...

Page 3: ...t sensor Semiconductor target GTF300 AQ hydrogen ethanol isobutene etc GTF300 VOC toluene xylene alcohol ammonia etc sampling method diffusion measure range 1 200 CIAQ Composite Index of Air Quality Refer GASTECH calibration curves or make them by user Resolution accuracy sampling time 1 CIAQ continuity alarm level high alarm resetable analog output 4 20 mA max load resistance 500 ohm N A relay ou...

Page 4: ...concentration of hydrocarbon compounds and hydrogen in the air the more pollution exists the higher CIAQ will show 2 Settings The following operating procedure describes the settings In the operation press NEXT key or idle 3 minutes the display will back to the CIAQ In the display press NEXT key to enter next function In the display press ADJ key the buzzer and flash lamp will action Press ADJ key...

Page 5: ...enter calibration function Press NEXT key to jump calibration function and enter next function Warning Except necessary do not execute calibration It is necessary to execute calibration after power on 7 days An error operating should loss accuracy In the display user has to finish calibration Press ADJ key to meet ambience CIAQ In the fresh air 1 is a recommended value But in some place user might...

Page 6: ...uzzer high limit the detector not only has audible alarm but also provide clear alphanumeric alarm message for users It is the CIAQ high alarm display Press NEXT key the buzzer will mute and the display will back to the normal display If the CIAQ is still higher than buzzer high limit this message and audible alarm will come again that will disappear until the CIAQ is lower than the buzzer high li...

Page 7: ...e of scent sense good but some persons might not accept the smell Although everybody has various different sense of smell that cannot define Anyway the smell depends on the concentration of hydrocarbon compounds in the air 5 2 Smoke detecting GTF300 AQ VOC is very sensitive of hydrogen which generated from smoking or incomplete combustion Therefore GTF300 AQ VOC is suitable for air conditioner man...

Page 8: ...fusion or high concentration that out of CIAQ range dilute detection is possible put GTF300 AQ VOC in the bottle and takes the sample gases then inject bottle and read the CIAQ Neither diffusion or dilute Silicon compounds gases is not suitable to use GTF300 AQ VOC e g SiH4 5 6 The best partner of canary People knew apply canary to detect unknown gas or toxic gas since long ago Canary will die whi...

Reviews: