Motor Control

It is your responsibility to contact a qualified

electrician and assure that the electrical installation is

adequate and in conformance with all national and local

codes and ordinances. The metal capacitor shell must

be grounded.

Determine the correct overload setting required to

protect the motor (see motor starter manufacturerʼs

recommendations). Select fuses, motor protective

switches or thermal protective switches to provide

protection. Fuses act as short circuit protection for the

motor, not as protection against overload. Incoming line

fuses must be able to withstand the motorʼs starting

current. Motor starters with thermal magnetic overload

or circuit breakers protect motor from overload or

reduced voltage conditions.

The wiring diagram supplied with the product provides

required electrical information. Check that power

source is correct to properly operate the dual-voltage

motors.

Your safety and the safety of others

is extremely important.

We have provided many important safety messages in

this manual and on your product. Always read and

obey all safety messages.

This is the safety alert symbol. This symbol

alerts you to hazards that can kill or hurt you and

others. The safety alert symbol and the words

“DANGER”and “WARNING”will precede all safety

messages. These words mean:

You will be killed or seriously injured if you donʼt follow

instructions.

You can be killed or seriously injured if you donʼt follow

instructions.
All safety messages will identify the hazard, tell you

how to reduce the chance of injury, and tell you what

can happen if the safety instructions are not followed.

Correct installation is your responsibility.

Make sure you

have the proper installation conditions and that

installation clearances do not block air flow.

Blocking air flow over the product in any way can cause

the product to overheat.

Mounting

This product can be installed in any orientation.

Mounting the product to a stable, rigid operating surface

and using shock mounts will reduce noise and vibration.

Accessories

Filters and mufflers are supplied with some models.

These should be checked periodically and replaced

when necessary. Please consult your Gast

Distributor/Representative for additional filter

recommendations.

DANGER

Plumbing

Remove plugs from the IN and OUT ports. Connect

with pipe and fittings that are the same size or larger

than the productʼs threaded ports. Be sure to connect

the intake and exhaust plumbing to the correct inlet and

outlet ports.

Ports will not support the weight of the

plumbing.

Install relief valves and gauges at inlet or outlet, or both,

to monitor performance. Check valves may be required

to prevent back streaming through the pump.

Electrical Connection

2

INSTALLATION

Electrical Shock Hazard

Disconnect electrical power at the circuit breaker

or fuse box before installing this product.
Install this product where it will not come into

contact with water or other liquids.
Install this product where it will be weather

protected.
Electrically ground this product.
Failure to follow these instructions can result in

death, fire or electrical shock.

Electrical Shock Hazard

This product must be properly grounded.
Do not modify the plug provided. If it will not

fill the outlet, have the proper outlet installed

by a qualified electrician.
If repair or replacement of the cord or plug is

necessary, do not connect the grounding wire

to either flat blade terminal. The wire with

insulation that is green with or without yellow

stripes is the grounding wire.
Check the condition of the power supply wiring.

Do not permanently connect this product to

wiring that is not in good condition or is

inadequate for the requirements of this product.
Failure to follow these instructions can result in

death, fire or electrical shock.

Summary of Contents for 70 - 3005 G443PL

Page 1: ...s and requires NO lubrication Pressure units may be used for both pressure and vacuum Consult your Gast Distributor Representative to use vacuum units for pressure Thank you for purchasing this Gast product It is manufactured to the highest standards using quality materials Please follow all recommended maintenance operational and safety instructions and you will receive years of trouble free serv...

Page 2: ...ow over the product in any way can cause the product to overheat Mounting This product can be installed in any orientation Mounting the product to a stable rigid operating surface and using shock mounts will reduce noise and vibration Accessories Filters and mufflers are supplied with some models These should be checked periodically and replaced when necessary Please consult your Gast Distributor ...

Page 3: ...ped with a power supply cord having a grounding wire with an appropriate grounding plug The plug must be plugged into an outlet that is properly installed and grounded in accordance with all local codes and ordinances Extension cords Use only a 3 wire extension cord that has a 3 blade grounding plug Connect extension cord plug to a matching 3 slot receptacle Do not use an adapter Make sure your ex...

Page 4: ...peration This one procedure will help to assure the productʼs performance and service life Solvent Cleaning Use only Gast recommended Solvent or other non petroleum based solvent Do Not use kerosene or ANY other combustible solvent to clean product 1 Remove the four bolts holding the head on 2 Remove filters and clean with Gast recommended solvent or other non petroleum based solvent Use compresse...

Page 5: ...NTY IS LIMITED SOLELY AT GASTʼS OPTION TO REPLACEMENT OF OR CURE OF SUCH NONCONFORMING OR NON DELIVERED GOODS OR RETURN OF THE PURCHASE PRICE FOR SUCH GOODS AND IN NO EVENT SHALL EXCEED THE PRICE OR CHARGE FOR SUCH GOODS GAST EXPRESSLY DISCLAIMS ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR USE OR PURPOSE WITH RESPECT TO THE GOODS SOLD THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE ...

Page 6: ...FAN DAA 1 AF533A 14 GRILLE 1 AF807 2 AF807 15 RIVET 4 AP534 8 AP534 16 VALVE PLATE ASSEMBLY 1 AP519 2 AP519 17 CRANKCASE COVER 1 AP526 2 AP526 18 CRANKCASE COVER SCREW 2 AP525 4 AP525 SERVICE KIT 1 K294A 2 K294A DAA DOA DOL SERIES Please reference the exploded views on the next page for the following model and parts table DOA shown The double ended DAA models not illustrated are two DOAs mounted b...

Page 7: ...EXPLODED PRODUCT VIEWS MODEL DOA VALVE PLATE ASSEMBLY Valve Plate Assembly available separately Valve Plate Assembly also includes items 7 8 as shown in the main exploded view 7 ...

Page 8: ... replace Muffler dirty Clean or replace Valves dirty or valves bent Clean or replace Relief valve set too high Inspect and adjust Relief valve set too low Inspect and adjust Plugged vacuum pressure line Inspect and repair Collapsed vacuum line Inspect and repair Low voltage wonʼt start Check power source Voltage wrong Check power source Cylinder misadjustment Realign Leaky hose or check valve Repl...