Gast 70 - 3005 G443PL Maintenance Manual Download Page 1

OIL-LESS DIAPHRAGM

VACUUM PUMPS & COMPRESSORS

O

PERATION

& M

AINTENANCE

M

ANUAL

Product Use Criteria:

• Pump only clean, dry air.

• Operate at 32ºF - 104ºF (0ºC - 40ºC).

• Protect unit from dirt & moisture.

• Do not pump flammable or explosive gases or

use in an atmosphere that contains such gases.

• Protect all surrounding items from exhaust air. This

exhaust air can become very hot.

• Corrosive gases and particulate material will

damage unit. Water vapor, oil-based contaminants

or other liquids must be filtered out.

• Consult your Gast Distributor/Representative

before using at high altitudes.

• This pump is oil-less and requires NO lubrication.

• Pressure units may be used for both pressure and vacuum.

Consult your Gast Distributor/Representative

to use vacuum units for pressure.

Thank you for purchasing this Gast product. It is manufactured to the highest standards

using quality materials. Please follow all recommended maintenance, operational

and safety instructions and you will receive years of trouble free service.

www.gastmfg.com

ISO 9001 & 14001 CERTIFIED

®Registered Trademark/™Trademark of Gast Manufacturing Inc., Copyright © 2002 Gast Manufacturing Inc.  All Rights Reserved.

Model DOA Shown

Model DAA Shown

1

PLEASE READ THIS MANUAL COMPLETELY BEFORE INSTALLING AND USING

THIS PRODUCT. SAVE THIS MANUAL FOR FUTURE REFERENCE AND

KEEP IN THE VICINITY OF THE PRODUCT

WARNING

PART NO. 70 - 3005 G443PL (Rev. D)

Summary of Contents for 70 - 3005 G443PL

Page 1: ...s and requires NO lubrication Pressure units may be used for both pressure and vacuum Consult your Gast Distributor Representative to use vacuum units for pressure Thank you for purchasing this Gast product It is manufactured to the highest standards using quality materials Please follow all recommended maintenance operational and safety instructions and you will receive years of trouble free serv...

Page 2: ...ow over the product in any way can cause the product to overheat Mounting This product can be installed in any orientation Mounting the product to a stable rigid operating surface and using shock mounts will reduce noise and vibration Accessories Filters and mufflers are supplied with some models These should be checked periodically and replaced when necessary Please consult your Gast Distributor ...

Page 3: ...ped with a power supply cord having a grounding wire with an appropriate grounding plug The plug must be plugged into an outlet that is properly installed and grounded in accordance with all local codes and ordinances Extension cords Use only a 3 wire extension cord that has a 3 blade grounding plug Connect extension cord plug to a matching 3 slot receptacle Do not use an adapter Make sure your ex...

Page 4: ...peration This one procedure will help to assure the productʼs performance and service life Solvent Cleaning Use only Gast recommended Solvent or other non petroleum based solvent Do Not use kerosene or ANY other combustible solvent to clean product 1 Remove the four bolts holding the head on 2 Remove filters and clean with Gast recommended solvent or other non petroleum based solvent Use compresse...

Page 5: ...NTY IS LIMITED SOLELY AT GASTʼS OPTION TO REPLACEMENT OF OR CURE OF SUCH NONCONFORMING OR NON DELIVERED GOODS OR RETURN OF THE PURCHASE PRICE FOR SUCH GOODS AND IN NO EVENT SHALL EXCEED THE PRICE OR CHARGE FOR SUCH GOODS GAST EXPRESSLY DISCLAIMS ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR USE OR PURPOSE WITH RESPECT TO THE GOODS SOLD THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE ...

Page 6: ...FAN DAA 1 AF533A 14 GRILLE 1 AF807 2 AF807 15 RIVET 4 AP534 8 AP534 16 VALVE PLATE ASSEMBLY 1 AP519 2 AP519 17 CRANKCASE COVER 1 AP526 2 AP526 18 CRANKCASE COVER SCREW 2 AP525 4 AP525 SERVICE KIT 1 K294A 2 K294A DAA DOA DOL SERIES Please reference the exploded views on the next page for the following model and parts table DOA shown The double ended DAA models not illustrated are two DOAs mounted b...

Page 7: ...EXPLODED PRODUCT VIEWS MODEL DOA VALVE PLATE ASSEMBLY Valve Plate Assembly available separately Valve Plate Assembly also includes items 7 8 as shown in the main exploded view 7 ...

Page 8: ... replace Muffler dirty Clean or replace Valves dirty or valves bent Clean or replace Relief valve set too high Inspect and adjust Relief valve set too low Inspect and adjust Plugged vacuum pressure line Inspect and repair Collapsed vacuum line Inspect and repair Low voltage wonʼt start Check power source Voltage wrong Check power source Cylinder misadjustment Realign Leaky hose or check valve Repl...