ENERGY SAVING RECOMMENDATIONS
INSULATION: Building insulation is one of the most important
steps of energy saving. Insulated building allows you to get more
energy using less fuel.
ADJUSTING
RIGHT
TEMPERATURE
VALUES:
Selecting
COMFORT and REDUCED TEMPERATURE values
will
save
energy. Excessively selected COMFORT temperature will increase
the energy consumption. To save more energy use REDUCED
TEMPERATURE function more often.
CORRECT PROGRAMMING: Selecting the correct operation
ranges for automatic mode will save energy.
INSTALLATION INSULATION: Insulation of pipes, collectors,
boilers, storage tanks and chimneys in the boiler room saves
energy. Installation pipes which will pass through unused spaces
must also be insulated.
WATER QUALITY: Water treatment will keep the water conditions
under constant control and saves energy.
REGULAR MAINTENANCE: Maintenance of the boiler once a year
and reviewing the system periodically is also important for energy
saving.
13
DISPOSAL
When
ALUBOX X-treme
boilers have to be disposed of, the
procedures determined by the local authorities must be followed.
Such wastes must be treated in accordance with the applicable
regulations.
Similarly, local regulations will be followed for the packaging
wastes.
Leaving the non-functional units, spare parts and
packaging materials in the environment and leaving
them accessible to children can be dangerous.
Such wastes must be treated in accordance with the
applicable regulations.
Ignoring this warning may harm, people, animals
and may cause property damage. Manufacturer is
not liable for damages that may arise in such cases.
43
Siphon will be cleaned and the drain line will be checked. Once the
condensate siphon has been cleaned, it must be filled with water
again. If there is a congestion in the drainage line, the slope has to
be checked.
Time / holiday settings which are made according to the requests of
the consumer will be checked.
Emission values
(CO
2 and O2) will be written to the service
document by operating the boiler at nominal, minimum and partial
load.
Boiler submission: After all maintenance operations are carried out,
the boiler will be submitted in a working position or stand-by
position according to the request of the consumer. Display reminder
for the next maintenance period will be programmed.
Creating a maintenance file: A file should be created to remember
the maintenance, date, replacement parts, recommendations and
warnings about the boiler and store with the service documents.