Installation, operation & maintenance
Instructions
To BE InSTAllED onlY on oR In A
non-ComBUSTIBlE EnCloSURE
Note: Recommended clearances must be
maintained.
Tools Required
Adjustable spanner
Phillips head screwdriver
Gas piping
1. (a) A minimum pipe diameter of 15mm is
required for inlet piping. A lever operated
shut-off valve should be installed within 1
metre of the appliance for servicing the
unit.
(b) Where it is not practical to install solid
tube AGA certified stainless steel braided
hose can be installed. This hose assembly
must comply with AS5601 Gas Installations,
pipe sizing tables and shall not exceed
3 metres in length. The internal diameter
of the hose must not be less than 10mm.
2. Check with local and state plumbing and
heating codes regarding sizing of the gas
lines.
3. All gas pipe connections must be sealed with
a gas pipe compound resistant to Natural
Gas.
4. Installation of a drip leg if required in the gas
supply line must conform to AS5601.
5. When checking for gas leaks, do not use an
open flame. Use a soap and water solution
and check for bubbles indicating gas leakage.
6. Installation of 1/8” NPT plugged tapping,
accessible for test gauge connections, is
required upstream of the gas supply
connection.
SERvICInG InSTRUCTIonS
Appliances should be serviced at least annually
and servicing must only be carried out by a
Licensed Plumber or Authorised Person.
Clean the Burner Ports and top with a Soft Brush.
Inspect and clean all combustion air inlets, then
replace the Burner ensuring it is firmly secured.
minimum Clearance for ventilation
Rear: 350 mm
Side: 300 mm
noTE To InSTAllER
BBQ Burner and side burner, drill the injectors
as per the data label specifications or contact
customer service on 1300 174 876 to order an
injector kit.
TEST oPERATIon oF APPlIAnCE
BEFoRE lEAvInG.
WARnInG
Improper installation, adjustment, alteration,
service or maintenance can cause injury or
property damage.
Read the instructions thoroughly before
installing or servicing this equipment.
THIS APPlIAnCE mUST noT BE
InSTAllED oR USED InDooRS.
nATURAl GAS APPlIAnCE.
To BE InSTAllED onlY BY An
AUTHoRISED PERSon.
THE AUTHoRISED PERSon WIll
PRovIDE A CERTIFICATE oF
ComPlIAnCE.
A suitable Australian Standard approved
natural gas pressure regulator must be
installed in the pipeline and be set at 1 kPa.
nATURAl GAS ConvERSIon