6
TEST FIRING HEATER
Test fire heater, following the lighting instructions. Leak test all gas connections with soapy water. Soap bubbles
indicate gas leakage. DO NOT use a match to test for gas leaks.
TROUBLE SHOOTING
Problem
Possible Causes
Solution
Main burner will
not light
No gas
Replace cylinder
Low gas pressure
Replace cylinder
Blockage in orifice
Remove blockage
Manual valve no in LOW or HIGH position
Position to HIGH
Note: If the appliance cannot be adjusted to perform correctly it should not be used until serviced or repaired.
White smoke may appear around the emitter grid during the first minute of initial firing.
Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage.
Any modifications or adjustments made to product without prior authority from the manufacturer will void any
warranty claims. Read the installation, operating and maintenance instructions thoroughly before installing or
servicing this equipment.
WARNING
LIGHTING INSTRUCTIONS
1. Ensure that the control knob is off. Slowly open
the gas cylinder valve.
2. Push in control knob and turn anti-clockwise to
HI whilst simultaneously pressing the red ignitor
button.
3. Check for flame at the burner. If burner does
not light immediately turn control knob to OFF
position and try again from the start. Allow 30
seconds between ignition attempts for gas to
dissipate. Several attempts may be necessary.
Failure to follow this lighting procedure may
result in flame roll out beyond the emitter grid.
4. With the burner alight keep control knob
depressed for 15 seconds.
5. For minimum heat push in and turn the control
knob to LO.
6. To turn heater off, turn the control knob to OFF.
HI
LO
OFF
PUSH
TO SPARK