3
2
2.
Adequate clearance around air openings into the
combustion chamber, clearances from combustible
materials, provisions for accessibility and for
combustion and ventilating air supply must be
maintained at all times when the appliance is
operating.
3.
Proper clearance from combustible materials must
be maintained at all times. The minimum clearances
are as follows:
Minimum Clearance from Combustibles
Side
915
mm
Rear
915
mm
Top 1
2
00mm
DO NOT locate this appliance under any overhead
enclosure. Avoid using near or under overhanging trees
and shrubs. Combustible materials should never be
within 1.
2
m of the top of the appliance.
Combustible materials are considered to be wood,
compressed paper, plant fibres, plastic, plexiglas or
other materials capable of being ignited and burned.
Such materials shall be considered combustible even
though flame proofed, fire-retardant treated or plastered.
Additional clearance may be required for glass, painted
surfaces and other materials which may be damaged by
radiant or convection heat.
INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS
IMPORTANT SAFETY RULES
This appliance must only be used in a well ventilated
area.
1. This appliance shall not be installed or used
indoors, in buildings, garages or any other
enclosed area.
2.
ALWAYS place the appliance on a firm and level
surface.
3.
DO NOT place articles on or against this
appliance.
4.
DO NOT use or store flammable materials near
this appliance.
5.
DO NOT use in windy conditions.
6.
DO NOT burn solid fuels in the appliance.
7. This is a decorative appliance only and any kind
of cooking is strictly forbidden.
8. Children and adults should be alerted to the
hazards of high surface temperatures, burns and
clothing ignition.
9. Children should be carefully supervised when
they are in the area of the appliance.
10.
NEVER hang anything including clothes or other
flammable items on the appliance.
11.
DO NOT use this appliance if any part has been
under water. Immediately call a qualified service
technician to inspect the appliance and to
replace any part of the control system and any
gas control that has been under water.
12.
DO NOT operate this appliance unless it is fully
assembled.
13.
DO NOT SPRAY AEROSOLS IN THE VICINITY
OF THIS APPLIANCE WHILE IT IS IN
OPERATION.
14. Remove any debris from within the grate area.
15. Installation and repair should be done by a
qualified service person. The appliance must
be inspected before use and at least annually
by a qualified service person. More frequent
cleaning may be required as necessary. It is
imperative that control compartment, burners
and circulating air passages of the appliance and
light be kept clean.
Prior to assembling your appliance, the following must be
reviewed. Compliance with the following should result in
satisfactory appliance operation. This instruction manual
should be retained for future reference. The installation
must conform with local codes or authority having
jurisdiction.
1. The appliance is intended for residential and
nonresidential outdoor spaces. The installation must
conform with New Zealand Standard 5601 “Gas
Installations”.
4. The appliance must be located on a solid table
which should be situated on a level and adequate
footing. Timber tables are recommended.
5.
The gas manifold supply pressure must be regulated
at 2.75 kPa utilising an approved regulator (supplied
with appliance).
6.
The appliance must be inspected before each use,
and at least annually by a qualified service person.
a.
The appliance area must be kept clear and free of
combustible materials, gasoline and other
flammable vapours and liquids.
b.
Gas orifices and burner must be kept clear of dirt
and cobwebs. Flow of combustion and ventilation
air through the perforated portions of the
appliance must not be obstructed. Cleaning with
a soft brush before use and at least every six
months is recommended.
915
mm
915
mm
915
mm
915
mm