background image

Installation, Operation and Maintenance Instructions

ESSENTIAL INFORMATION

Standards Australia formulates standards and codes for 
such products, to which SITRO Group Australia (SGA) 
complies in the manufacture of all heaters, so as to provide 
a product of premium quality and of a high safety standard.  

SGA will void any warranty applicable to the product if any 
component of the patio heater is tampered with, or altered.  

To have these units altered or serviced by an unauthorised 
person may render the product inefficient, and at worst 
dangerous.

SERVICING INSTRUCTIONS

Appliances should be serviced at least annually and 
servicing must only be carried out by a Licensed Plumber or 
Authorised Person.  

1.   Remove Emitter Grid from Burner Housing.  To remove 

Burner loosen the holding screw located at base of 
Burner tube through opening in gas control housing then 
turn Burner anticlockwise and pull free.

2.   Clean the Burner Ports and top with a Soft Brush.  

Inspect and clean all combustion air inlets, then replace 
the Burner ensuring it is firmly secured.

3.   Clean pilot head, thermocouple tip and spark igniter 

using a soft wire brush.

4.   Check operation of the pilot, igniter and the 

thermocouple.  Should new parts be required contact the 
Supplier or Sitro Group Australia.

INSTALLATION

Natural Gas Heaters must be installed by an Authorised 
Person.   

Heaters can be floor mounted or suspended overhead on 
brackets.   

Floor mounted heaters must be permanently fixed on a level 
and adequate footing.   

Brackets for suspended installation must be permanently 
fixed to a solid structure.   

Positioning of both floor mounted and suspended heaters 
must maintain required clearances.  

i.e. 500mm above, 500mm on all sides and 1970mm below 
the heater emitter mesh.   

It is a Standards Australia requirement that an approved 
metal tube such as copper or galvanized steel or an AGA 
certified stainless steel braided hose assembly be utilised to 
convey gas to the burner head, and must be installed by an 
authorised person, i.e. licensed plumber.   

A Natural Gas Patio Heater is not designed for relocation 
to varying locations, so the most preferable permanent 
location should be selected prior to installation.

CARE

We strongly recommend the use of a patio heater cover to 
protect your patio heater when not in use.  

All patio heaters must have the burner head covered when 
not in use.  This will prevent blockages occurring, which 
may lead to the patio heater not igniting when required 
for use on the next occasion, or causing the burner not to 
function efficiently.  

Such blockages can be caused by the accumulation of dust 
on various components in the burner head and by spider 
webs.  Covering the burner head will also assist in reducing 
the weathering effects of the outdoors, as well as corrosion 

Type of Gas

Natural

Consumption

45 MJ/h

Operating Pressure

1 kPa

Injector Size

3.25 mm

Heater specifications can be found on the data label located on the pole.

Summary of Contents for NG1P45

Page 1: ...ller must leave these instructions with the consumer FEATURES The ideal solution for extending the season for outdoor entertaining Creates a stylish and attractive ambience Casts an approximate 3 to 5 metre circle of radiant sun like warmth Piezo ignition Adjustable heat output Flame safeguard system for enhanced safety Stainless steel burner for extra long term reliability Durable and weather res...

Page 2: ...ble vapours and liquids b Gas orifices and burner must be kept clear of dirt and cobwebs Flow of combustion and ventilation air through the perforated portions of the heater must not be obstructed Cleaning with a soft brush before use and at least every six months is recommended c All gas connections should be checked for leaks utilising a soap solution Never use a flame for this purpose d The fla...

Page 3: ...r mounted or suspended overhead on brackets Floor mounted heaters must be permanently fixed on a level and adequate footing Brackets for suspended installation must be permanently fixed to a solid structure Positioning of both floor mounted and suspended heaters must maintain required clearances i e 500mm above 500mm on all sides and 1970mm below the heater emitter mesh It is a Standards Australia...

Page 4: ...ater must be permanently fixed on a level and adequate footing Attachment may be made utilising the holes located in the heater base plate An AGA approved natural gas pressure regulator must be installed in the pipeline at the base of the heater and be set at 1 kPa Any modification to the heater not described in the installation instructions may compromise the safety of this appliance Special conc...

Page 5: ... segments of the reflector to overlap together 2 Secure using 8 screws and dome nuts as illustrated STEP A 1 Place the round part of the reflector over the 4 assembled segments 2 Secure using 4 screws and dome nuts as illustrated STEP B ...

Page 6: ...ose to the head feeding it through the required post assembly Where a hose assembly is to be used to connect an appliance it must comply with AS5601 2004 Gas Installations pipe sizing tables and shall not exceed 3 metres in length The internal diameter of the hose must not be less than 15mm STEP 3 a Slide assembled gas pipe and heater head into post b Turn heater head so elbow fitting lines up wit...

Page 7: ...l No NG1P45 NG2P45 For Outdoor Use Only Minimum Clearance from Combustible Surfaces Combustible materials are considered to be wood compressed paper plant fibres plastic or other materials that are capable of being ignited and burned ...

Page 8: ...odel No NGW45 For Outdoor Use Only Minimum Clearance from Combustible Surfaces Combustible materials are considered to be wood compressed paper plant fibres plastic or other materials that are capable of being ignited and burned ...

Page 9: ...VARIOUS CONFIGURATIONS Version 1 Bracket Mounted to Ceiling Version 2 Bracket Mounted to Wall Version 3 Bracket Mounted to Brick Pillar Wall ...

Page 10: ... or adjustments made to product without prior authority from the manufacturer will void any warranty claims Read the installation operating and maintenance instructions thoroughly before installing or servicing this equipment LIGHTING INSTRUCTIONS Warning White smoke may appear around the radiant head during the first minutes of the initial firing Step 1 Ensure that the control knob is off Slowly ...

Page 11: ...see Example 1 Within a partial enclosure that includes an overhead cover and no more than two walls see Example 2 3 Within a partial enclosure that includes an overhead cover and more than two walls the following will apply at least 25 of the total wall area is completely open and at least 30 of the remaining wall area is open and unrestricted see Example 4 5 In the case of balconies at least 20 o...

Page 12: ...Gasmate is a registered trademark of Sitro Group Australia Pty Ltd www sitro com au AberGas Ltd Hamilton N Z www abergas co nz ...

Reviews: