3.  Proper clearance from combustible materials must be 

maintained at all times. The minimum clearances are 
as follows:

Minimum Clearance from Combustibles:
Side 
 

500 mm 

 

Rear  

500 mm

Ceiling  

1000 mm

Combustible materials are considered to be wood,  

 

compressed paper, plant fibres, plastic, plexiglas or other 
materials capable of being ignited and burned. 
Such materials shall be considered combustible even 
though flame proofed, fire-retardant treated or plastered. 
Additional clearance may be required for glass, painted 
surfaces and other materials which may be damaged by 
radiant or convection heat.
4.   Heaters must be placed on a level and adequate 

footing and be readily accessible.

5.   The gas manifold supply pressure must be regulated at 

2.75 kPa utilising an AGA approved regulator (supplied 
with heater).

6.   The appliance must be inspected before each use, and 

at least annually by a qualified service person.

a.   The appliance area must be kept clear and free of 

combustible materials, gasoline and other flammable 
vapours and liquids.

b.   Gas orifices and burner must be kept clear of dirt 

and cobwebs. Flow of combustion and ventilation air 
through the perforated portions of the heater must not 
be obstructed.  Cleaning with a soft brush before use 
and at least every six months is recommended.

c.   All gas connections should be checked for  

leaks utilising a soap solution. Never use a flame for 
this purpose.

d.    The flame pattern should be visually checked 

whenever heater is operated. If flames extend beyond 
surface of the guard the appliance should be turned 
off and should not be operated again until the unit is 
serviced and or repaired. 

e.    Any cleaning agent used on the heater should be of a 

non-combustible and non-corrosive nature.

f.    The stainless steel emitter normally does not require 

cleaning and should

 NEVER be painted.

Important Safety Rules

This appliance must only be used in a well ventilated 
area.
1.  This appliance shall not be installed or used  

indoors, in buildings, garages or any other 
enclosed area.

2. 

DO NOT place articles on or against this 
appliance.

3. 

DO NOT use or store flammable materials near 
this appliance. 

4.  Children and adults should be alerted to the 

hazards of high surface temperatures, burns and 
clothing ignition.

5.  Children should be carefully supervised when 

they are in the area of the appliance.

6. 

NEVER hang anything including clothes or other 
flammable items on the appliance.

7.  

DO NOT operate this appliance unless it is fully 
assembled with burner guard in place.

8.  

DO NOT SPRAY AEROSOLS IN THE VICINITY 
OF THIS APPLIANCE WHILE IT IS IN 
OPERATION.

9.  Installation and repair should be done by a 

qualified service person. The appliance must be 
inspected before use and at least annually by 
a qualified service person.  It is imperative that 
control compartment, burners and circulating air 
passages of the heater be kept clean.

Prior to assembling your appliance, the following must 
be reviewed. Compliance with the following should result 
in satisfactory heater operation. This instruction manual 
should be retained for future reference. The installation 
must conform with local codes or authority having 
jurisdiction.
1.   The patio heater is intended for heating residential 

and non-residential outdoor spaces.  The installation 
must conform with local codes and with the Australian 
Standard AS/NZS 5601.

2.   Adequate clearance around air openings into the 

combustion chamber, clearances from combustible 
materials, provisions for accessibility and for 
combustion and ventilating air supply must be 
maintained at all times when the appliance is 
operating.

Summary of Contents for DELUXE AH2067ODS

Page 1: ...ng or servicing this equipment FOR OUTDOOR USE ONLY PROPANE GAS Model No AH2067ODS AH2066 The ideal solution for extending the season of outdoor entertaining Creates a stylish and attractive ambience Rotary ignition Includes a safety tip over switch that halts supply of gas to the unit should it be accidentally knocked over Oxygen depletion system for enhanced safety Stainless steel burner for ext...

Page 2: ...sed on the heater should be of a non combustible and non corrosive nature f The stainless steel emitter normally does not require cleaning and should NEVER be painted Important Safety Rules This appliance must only be used in a well ventilated area 1 This appliance shall not be installed or used indoors in buildings garages or any other enclosed area 2 DO NOT place articles on or against this appl...

Page 3: ...and the heater must be disconnected and the cylinder stored in accordance with the Standard for Storage and Handling of Liquefied Gases 13 The appliance has been designed with several safety features which include a tip over switch IMPORTANT Storage of an appliance indoors with the cylinder attached is only permitted if the size of the cylinder complies with AS NZS 1596 otherwise cylinders must be...

Page 4: ...r house body with five M5 x 8mm long screws washers and nuts STEP 3 Securely attach the hose to the burner head and the regulator to a gas cylinder check the connections for leaks using a soapy water solution STEP 4 Attach the door hinges to the body and the door with 8 M5 screws and nuts AREA HEATER ASSEMBLY Burner head assembly Flexible hose assembly M5 screw 8mm long M5 nuts Cylinder house body...

Page 5: ...e Only Minimum Clearance from Combustible Surfaces Combustible materials are considered to be wood compressed paper plant fibres plastic or other materials that are capable of being ignited and burned 500mm 1330mm 630mm 540mm 1000mm ...

Page 6: ...t without prior authority from the manufacturer will void any warranty claims Read the installation operating and maintenance instructions thoroughly before installing or servicing this equipment LIGHTING INSTRUCTIONS WARNING White smoke may appear around the radiant head during the first minutes of the initial firing 1 Ensure that the control knob is off Slowly open the gas cylinder valve 2 Push ...

Page 7: ...n which the appliance is used shall comply with the following An enclosure with walls on all sides but at least one permanent opening at ground level and no overhead cover see Example 1 Within a partial enclosure that includes an overhead cover and no more than two walls see Example 2 3 Within a partial enclosure that includes an overhead cover and more than two walls the following will apply At l...

Page 8: ...e call Customer Service Australia Only 1300 174 876 Hours of operation Monday to Friday 8am 5pm EST Do not return to place of purchase Keep your purchase receipt this will be required to make any claims under the 12 month warranty ...

Reviews: