5
4
GENERAL ASSEMBLY
Connecting & Disconnecting to
the gas source
Familiarise yourself with the general information and
safety guidelines located at the front of this manual.
Check:
1. The cylinder is filled. A sloshing sound will be
heard when shaken.
2. The burner controls are in the ‘OFF’ position
Connecting:
1. Ensure cylinder valve is in its full off position.
2. Check for any damage to either the cylinder
connection or the hose. NEVER attempt to use
damaged equipment.
3. When connecting the hose to the cylinder
tighten the nut to a positive stop by hand
or spanner.
4. Open cylinder valve fully. If a leak can be heard
at either end of the hose turn cylinder off and
tighten joint. Wait 5 minutes before re-testing
and use a soapy water solution to check the
joint. If bubbles appear, the connection will
need to be re-tightened.
Disconnecting:
1. Ensure the burner control is in the
‘OFF’ position.
2. Ensure cylinder valve is in the full off position.
For storage and cylinder exchange, disconnect hose
at the cylinder only, DO NOT disconnect hose from
appliance.
LIGHTING PROCEDURE
Burner Operation &
Ignition System Check
1. Turn the control knobs clockwise to “OFF”
position.
2. Connect the regulator to the gas bottle. Turn
the gas supply “ON” at the cylinder. Check
with the use of soapy water for any gas
leakage between the bottle and the regulator
3. Push down a control knob and keep
pressing whilst turning anti-clockwise
to the “HIGH” position whilst also pressing the
ignition button (a clicking sound is heard), this
will light the burner. If the burner does not light,
repeat this process.
4. If the burner still does not light, turn the control
knob to ‘OFF’ wait 5 minutes and repeat step 3.
Nominal Hourly Gas Consumption
BBQ
Model
Number
Gas
Type
Number
of BBQ
Burners
Injector
Size Main
Burners
Injector
Size Side
Burner
Injector
Size Rear
Burner
Total Gas
Consumption
MJ/h
Gas
Pressure
kPa
BQ1011P
Propane
6
0.98mm
1.13mm
1.00mm
96 MJ/h
2.75 kPa
MJ/h each
11.6 MJ/h
15 MJ/h
11.5 MJ/h
Natural
Gas
6
1.6mm
1.70mm
1.75mm
99 MJ/h
1.0 kPa
MJ/h each
12 MJ/h
14 MJ/h
13 MJ/h
BQ1010P
Propane
4
0.98mm
1.13mm
1.00mm
73 MJ/h
2.75 kPa
MJ/h each
11.6 MJ/h
15 MJ/h
11.5 MJ/h
Natural
Gas
4
1.6mm
1.70mm
1.75mm
75 MJ/h
1.0 kPa
MJ/h each
12 MJ/h
14 MJ/h
13 MJ/h