10" 1/16
(255.8 mm)
=
=
20" 35/64
(522 mm)
20" 5/16
(515.5 mm)
minimum
1" 1/4
(31.8 mm)
minimum
7" 7/8
(200 mm)
=
=
Provide a hole for
gas connection to
1/2” diameter pipe
fitting.
Provide hole
for electrical
connection in
this area
Area for
electrical
connection
Gas line opening:
Provide a suitable hole on the bottom of cutout. The centre of hole shall be
10″1/16 (255.8 mm) from the centre of cutout to the left side and 20″35/64 (522
mm) from the front corner of cutout to the back.
Grounded outlet:
The electric cord with 3-prong ground plug has a length of 48″(1220 mm).
Grounded outlet should be located in an area 7″7/8 (200 mm) below the bottom
of cutout and only on the right side of the cabinet (from the centre to the right side
of the cabinet).
A suitable hole has to be provided on the bottom of the cutout, in an area
positioned on the right rear corner (1″1/4 (31.8 mm) maximum from the right side
of cutout and from the rear corner to maximum 20″5/16 (515.5 mm) from the front
corner of cutout), to pass the appliance cable.
Fig.13
16
www.gaslandchef.com
8350 Patriot Blvd STE B, N. Charleston, SC 29418
1 (844) 538-7890