Flame too high on High
setting.
Regulator faulty(Gas
pressure is too high).
Incorrect injector fitted.
Small flame on High
setting.
Regulator faulty.
Gas supply pressure low.
Incorrect injector fitted.
Blocked injector or gas
supply tube.
Incorrect utensil size.
Choose a suitable utensil.
At minimum flame setting
the flame is too high.
Turndown control setting
incorrect.
Adjust the minimum screw.
Uneven flame pattern or
slight flame lifting.
Burner ports blocked or
burner dislocation.
Remove, clean and replace
burner. Reassemble the burner.
Burner goes out when
control knob released.
Flame safeguard not
activated.
Re-light, allow more time for
flame safeguard to activate.
Flame safeguard faulty
connection or broken.
Gas supply off.
Check gas supply valve on.
Burner not aligned properly.
Burner ports blocked.
Remove and re-fit burner.
Burner not lighting when
spark ignition working.
Check plugged in and switched
on. Check mains circuit breaker.
Check the spark cable if loose.
Remove and re-fit burner.
Loose sparker cable.
Burner not aligned properly.
No power.
PROBLEM
POSSIBLE CAUSES
WHAT TO DO
No spark when gas
control knob depressed.
Check the thermocouple cable
connection if loosen or broken.
Choose a correct regulator.
Check the gas supply if run out.
Check the injector if correct.
Check the the injector and gas
supply tube if blocked.
Choose a correct specification
gas regulator(out let pressure)
Check injector if correct and
replace it.
Incorrect utensil size.
Choose a suitable utensil.
Gas regulator installation
direction faulty.
Reverse the direction to reinstall.
Installed a high pressure
gas regulator.
Replace a correct pressure gas
regulator.
Flame tips are very
yellow
Incorrect gas supply type or
incorrect gas regulator.
Check the gas supply type and
gas regulator if correct.
24
www.gaslandchef.com
3330-A Marathon Ct Charleston, SC 29418
1 (844) 538-7890
Summary of Contents for Pro GH2122SF
Page 27: ......