7. Ignition test requires that the burner can be lit in 5 seconds normally, after 1
minute the flame is stable, there should be no liftedflame and yellow fire.
8. Similarly, when use in NG status, turn the marked NG arrow upwards and
tighten it to the screw cap(Fig.21). Repeat the above operation. The outlet
pressure requires to be 4 ± 1 in w.c.
9. After the conversion is completed, the conversion label in the accessory bag
needs to be attached next to the original la bel.
Incorrect flame:
lifting off the burner
Fig.22 (Incorrect and good flame patterns)
Good flame:
well-defined blue flame
with slight yellow tipping
Original
label
Conversion
label
(Product bottom)
Injector dimameter:
1.62mm
Fig.23
162
1#: Wok burner(Injector: NG-ø1.62mm/Propane-1.06mm)
2#: Rapid burner(Injector: NG-ø1.5mm/Propane-0.97mm)
3#: Semi-rapid burner(Injector: NG-ø1.14mm/Propane-0.75mm)
4#: Auxiliary burner(Injector: NG-ø0.83mm/Propane-0.56mm)
17
www.gaslandchef.com
3330-A Marathon Ct Charleston, SC 29418
1 (844) 538-7890
Summary of Contents for Pro GH2122SF
Page 27: ......