MDE-5411A ForeHB Islander Prime Installation Manual · October 2018
Page 17
3.5 Security and Protection
System Overview
3.4.9 EMV Option
The pedestal can be supplied with an optional EMV reader set for payment with bank cards.
This feature is not currently offered, but will be available at a future date.
3.4.10 Communication Interfaces
Islander Prime comes equipped with three slots to house communication interfaces embedded
in slot blades. Slots 1 and 2 may house either mechanical or electronic interfaces, and slot 3
may only house electronic interfaces. In the order form, it is also required to define the part
number for the specific communication interface blades in use. The following communication
interfaces are available (see
):
Table 1: Communication Interfaces
No.
Pump Interface Blade
Part Number
1
Islander Prime 2M Blade
M15778B001
2
Islander Prime 4M Blade
M15778B001
3
Islander Prime 4x 485 Blade
M15778B001
4
Islander Prime 4x Tokheim Blade
M15778B001
5
Islander Prime 4x Current Loop Blade
M15778B001
6
Islander Prime 2x 422 + 2x 232 Blade
M15778B001
3.5 Security and Protection
All transactions performed in Islander Prime are secured and protected. The following
describes the security features of Islander Prime in detail.
3.5.1 Authorization
The contactless tags include Triple DES encrypted data for user identification and billing.
Consequently, Islander Prime includes a special Security Access Module (SAM) for
decryption and matching identification. Upon tag reading, Islander Prime attempts to decrypt
the string from the tag and disregards tags whose security scheme does not match the Islander
Prime internal SAM.
3.5.2 Network
The Ethernet
®
LAN is isolated from the external WAN by the nOrCU. In case of remote
maintenance, a firewall should be applied either at the router level or preferably at the
homebase station level.
3.5.3 RF Network
Islander Prime IEE 802.15.4 RF network is encrypted, using the AES 128 security standard.