MDE-4863 Gasboy® 9800A or 2600A Pump Interface Kits Installation Instructions · October 2009
Page 9
Pulse-out I/F Board (M06587A001) Jumper Settings
12
Attach the Bezel. Ensure that the Bezel is seated properly to ensure a watertight seal.
13
Attach and lock the front panel.
14
Turn on the Circuit Breakers.
Pulse-out I/F Board (M06587A001) Jumper Settings
Jumpers JP1, JP2, and JP3
This Board Assembly can be configured for use in one of the following pump/dispenser
configurations:
• Single-channel, Dual/Single-hose Pulse-out I/F (see
• Dual-channel, Single-hose Pulse-out I/F (see
The chart below shows the jumper settings and wires to connect to in the Junction Box, based
on the configuration.
Check JP1 - JP3 jumpers and change them, if necessary. The jumper settings must be changed
only when the power to the pump/dispenser is removed, to protect the circuit that they are
connected to.
For models 9800A, 2600A, or 9800Q, the P3 connector is not connected.
Jumper Settings
Single-channel,
Dual/Single-hose Pulse-out I/F
(Default Setting)
Dual-channel,
Single-hose Pulse-out I/F
(C07357 kits)
Wire Color
JP1 Position 1
JP2 Position 1
JP3 Open
JP1 Position 2
JP2 Position 2
JP3 Open
Red
Pulse-out Side 1
Pulse-out Side1A
Green
Pulse-out Side 2
Pulse-out Side1B
White
Common Return
Side 1A Return
Black
No Connection
Side 1B Return