MASTER
SLAVE
MASTER
OUTPUT
SLAVE
INPUT
INPUT
CH1
CH2
OUTPUT
CH1
CH2
DAISY-CHAIN
PWR
PRT
0.2V
70Hz
12dB
90Hz
250Hz
180
10V
10Hz
0dB
30Hz
30Hz
0
REMOTE
SPEAKER
OUTPUTS
GAIN
SUB
SONIC
BASS
BOOST
BASS
FREQ.
LPF
PHASE
SHIFT
1) INPUT
Minimum level input of 0.2V is essential for correct operation.
2) OUTPUT
Output RCA for signal routing to another amplifier.
3) GAIN (10V ~ 0.2V)
Matches the output voltage of the head unit’s RCA line-outs to the input section.
4) SUBSONIC FILTER (10Hz ~ 70Hz @ 24dB OCTAVE SLOPE)
Control the high pass point for the speaker outputs to eliminate xtreme low frequencies.
5) LOW PASS FILTER (30Hz ~ 250Hz @ 24dB OCTAVE SLOPE)
Controls the low pass points for speaker outputs.
6) BASS BOOST
Variable bass boost with 0-12 dB @ 30Hz ~ 90Hz.
7) PHASE CONTROL
Variable phase adjustment from 0~180 degrees
8) REMOTE LEVEL CONTROL PORT
Used for connecting to external wired remote controller.
9) REMOTE CONTROL (OPTIONAL ITEM)
Turn knob clockwise to increase level and likewise, turn knob counter clockwise decrease level.
10) MASTER OUTPUT / SLAVE INPUT
For linkable connection of 2 same amplifiers. Minimum impedance is 2 .
In this mode, the master amplifier will control gain settings on the subsequent slaved amplifier.
POWER & PROTECTION INDICATOR
Power LED, green-lit or blue-lit shows correct operation. Protect LED, Red-lit shows general malfunction,
faulty connection or thermal protection.
10)
Connect preamp signal cables from head unit to RCA input of amplifier.
11)
SPEAKER OUTPUTS
Amplifier connection to loudspeakers. Minimum size of speaker cable is 12 gauge.
Minimum impedance for single unit is 1 .
Minimum impedance in linked connections is 2 .
Panel Layout
(COMPETITION 7000.1D / 12000.1D)
4