VINCELL LT 5.0" Boxed
Manual
9
Resistive Touch
Type
4-wire analog resistive
Linearity
±1.5%
Surface Treatment
Antiglare
Power Supply and Consumption
Supply [V DC]
Nom. 12 ~ 24
Min./Max. 9 ~ 30
Consumption [W]
Typ. 6.0
Internal Backup Battery
Type
3 V lithium manganese dioxide Type CR1220
Lifetime (RTC only)
Approximately 8 years, depending on application
Housing
Back Cover
1.4016 high quality steel, polished, 0.8mm
Front
Frame 4mm AIMg3
Décor
Décor 180µ ± 10% polyester film, anti-glare, 91% ± 2% luminous
transmission, pencil hardness 3H
Protection Class
IP 66
Approximate Dimensions
W x H x D [mm]
149.0 x 100.2 x 29.7
Weight [g]
290
Environment
Humidity [%RH]
5 ~ 90 (non condensating)
Operating Temperature [°C]
0 ̴ +60
Storage Temperature [°C]
-
20 ̴ +70
Max. Operating Altitude [m]
3,000
Max. Storage/Transit
Altitude [m]
10,000
Noise Level [db(A)] @ 1m
<<40 (fanless design)
Lifetime
Backlight Lifetime
6
LCD
Display [h]
20,000
Operating Lifetime Touch
100,000 (by pen), 1,000,000 (by finger)
MTBF
7
[h]
≥ 50,000
6
Backlight lifetime is dictated by the LCD manufacture´s specification. Backlight lifetime is the approximate time at which
the brightness decreases to half of its original brightness. Reduction of brightness due to backlight lifetime is not
considered as failure. It is a natural aging of all electronic components.
7
Electrical products use the industrial standard term Mean Time between Failure (MTBF) as a statistical prediction of the
elapsed time between failures in a large population of systems.
The MTBF of all Garz & Fricke HMI products shall be 50,000 hours
A failure is anything that causes the product not to function to its specifications
Reduction in brightness due to backlight lifetime is not a failure
If the LCD used in the system exceeds its pixel defect specification it is consideredas a failure
Summary of Contents for VINCELL LT
Page 1: ...VINCELL LT 5 0 Boxed Manual For PCB revision 0 7 or for HW 1 1 or later ...
Page 19: ...VINCELL LT 5 0 Boxed Manual 19 Technical Appendix For PCB revision 0 7 or for HW 1 1 or later ...
Page 21: ...VINCELL LT 5 0 Boxed Manual 21 Annex B Mechanical specifications B 1 Mechanical Drawings Tbd ...
Page 22: ...VINCELL LT 5 0 Boxed Manual 22 Annex C Quality and Incoming Inspections C 1 Display ...
Page 23: ...VINCELL LT 5 0 Boxed Manual 23 ...
Page 24: ...VINCELL LT 5 0 Boxed Manual 24 ...
Page 25: ...VINCELL LT 5 0 Boxed Manual 25 ...
Page 26: ...VINCELL LT 5 0 Boxed Manual 26 ...