CAN/RS-485 Interface (X39)
6.4
Pin Name
Description
Level
1
GND_CAN_RS485
Ground for CAN and RS485 group
2
CAN1_TERM
To enable CAN1-Termination, bridge
with CAN1_H
3
CAN1_H
CAN bus 1 high
-24c+24 V
4
CAN1_L
CAN bus 1 low
-24c+24 V
5
CAN1_TERM
To enable CAN1-Termination, bridge
with CAN1_L
6
RS485_TERM
To enable RS485-Termination: bridge
with RS485_A
7
GND_CAN_RS485
Ground for CAN and RS485 group
8
n.a.
9
RS485_Y
TX+
-7c+12 V
10
RS485_Z
TX-
-7c+12 V
11
RS485_A
RX+, to enable Half-Duplex: bridge with
RS485_Y
12
RS485_B
RX- , to enable Half-Duplex: bridge with
RS485_Z
Header: Molex 43045-1200 Micro-Fit 12p
Plug: Molex 43025-1200 Micro-Fit 12p, crimp contact Molex 43030-0007
Shielding with 6,3 mm male spade terminal connector