RS-232/MDB (X13)
6.7
RS-232/RS-232
Pin Name
Description
Level
1
GND
Ground
2
RS232_TXD1
Port#1: Transmit data (Output)
3
RS232_RXD1
Port#1: Receive data (Input)
4
RS232_RTS1
Port#1: Request-to-send (Output)
5
RS232_CTS1
Port#1: Clear-to-send (Input)
6
GND
Ground
7
RS232_TXD2
Port#2: Transmit data (Output)
8
RS232_RXD2
Port#2: Receive data (Input)
9
RS232_RTS2
Port#2: Request-to-send (Output)
10
RS232_CTS2
Port#2: Clear-to-send (Input)
Header:
Molex 43045-1000 Micro-Fit 10p
Plug: Molex 43025-1000 Micro-Fit 10p,
crimp contact Molex 43030-0007
Shielding with 6,3 mm male spade terminal connector
RS-232/MDB (X13) is not galvanic isolated from System-GND/Housing
RS-232/MDB
Pin Name
Description
Level
1-6
Identical to standard (pls. see 0)
7
MDB_TXD
MDB: Transmit data (Output)
8
MDB_RXD2
MDB: Receive data (Input)
9
MDB_WakeUp
MDB: WakeUp Signal (Output)
10
MDB: WakeUp PullUp VCC
0…5 V