Digital I/O (X14)
6.3
Pin Name
Description
Level
1
DIG_IN1
Input 1
0V
Low Typ. 8,3
mA / 24 V
2
DIG_IN2
Input 2
3-36V
High
3
GND_DIO
Ground for digital IO group
4
GND
Common ground, can be bridged
with GND_DIO, when galvanic
isolation is not required
5
DIG_OUT1
Output 1
0V
Low Max. 800
mA / 24 V
6
DIG_OUT2
Output 2
Vcc_DI O High
7
Vcc_DIO
Supply input for digital IO group
<36 V
8
Vcc
Supply output, can be bridged
with Vcc_DIO, when galvanic
isolation is not required
Directly connected to the
supply (x1) without fuses
or surge protection!
Vcc_In
Header:
Molex 43045-0800 Micro-Fit 8p
Plug: Molex 43025-0800 Micro-Fit 8p, crimp contact Molex 43030-0007
Shielding with 6,3 mm male spade terminal connector
Digital I/O (X14) is not galvanic isolated from System-GND/Housing