gartenpirat para Instructions For Use Manual Download Page 2

zip wire ‘para’ - kabelbaan ‘para’  - télépherique ‘para’

Seilbahn ‘para’ - Teleférico ‘para’  - teleferica ‘para’

Instructions

 

for

 

use

 

-

 

M244.01 - zip wire ‘para’

Instructions for use

1. Please keep this instruction sheet safely for future reference, and ensure that you review it with all users.

2. Inappropriate use or faulty application of the product is explicitly forbidden and absolves the manufacturer of all liability.

3. The use of the item is allowed only under continuous supervision by an adult. The product is only intended for use as 

a zip wire between two points, for 1 user older than 8 years and with a maximum weight of up to 80 kg.

4. This product corresponds to all security aspects according to the European standards EN71-1, EN71-2, EN71-3 and 

EN71-8. This product is for family domestic use only and intended for indoor and outdoor use.

5. The zip wire should only be used after it has been properly installed according to the following guidelines.

6. The  application of the item as part of a play frame or any other construction will have to be such that it excludes all 

risk of entrapment.

7. When mounting or assembling the product, attention should be given to the minimum required distance between the 

product and eventual obstacles: walls, fencing, … This distance should be a minimum of 2 metres 

(see image I)

.

8. In this safety area no hard, angular or pointed objects should be present. The surface underneath the product 

should be flat and shock absorbing. The product must not be placed on tarmac, concrete or any other hard surface. We 

advise the removal and storage of all accessories during winter because the characteristics of the soil (when frozen) 

are not suitable for safe play.

9. Please ensure that the tree, branch or construction to which the zip wire is attached, is able to support a weight of 

300 kg.

Part list

Take all parts out of the packaging and check if anything is damaged, and if all parts are present.

Tools required

(1) pencil

(2) ratchet spanner with cap 7

(3) ratchet spanner with cap 13

(4) wire-shears

Instructions for cable Height

In order to assemble the zip wire correctly and safely, the following height requirements need to be followed. One end 

of the cable must be mounted at a higher level than the other end. These heights are dependant on the height of the 

user and the distance between the fixing points. In order to determine the right heights, the following steps must be 

followed:

1. Measure the height of the user. If there is more than one user, and the difference in height is less than 15 cm, use the 

height of the tallest user. If the difference is more than 15 cm, the zip wire needs to be adjusted every time the user’s 

height is outside the specified range.

2. Add 75 cm to the measured height of the user and mark this point on the tree or construction frame.

3. Measure the distance between the 2 fixing points. Determine the corresponding height in the following table and mark 

this height on the tree / construction at the other side.

5

6

7

8

7

A

B

C

(1)

(2)

(3)

(1) cable spanner

(2) rubber sleeve

(3) trolley

zip wire

cable (wedged)

3x

cable tensioners

D

2x

nut caps for cable spanner

7

13

(4)

(3)

(2)

(1)

Summary of Contents for para

Page 1: ...d dlers risk of falling ATTENTION Ne convient pas aux enfants de moins de 3 ans sans quipement sp ciale pour les petits enfants danger de chute WAARSCHUWING Niet geschikt voor kinderen jonger dan 3 ja...

Page 2: ...duct must not be placed on tarmac concrete or any other hard surface We advise the removal and storage of all accessories during winter because the characteristics of the soil when frozen are not suit...

Page 3: ...lways use the product under supervision of an adult 5 Always check the structure fixings trolley cable tensioners cable spanner and cable before using the zip wire 6 Do not allow children under next t...

Page 4: ...pio attorno all albero o struttura di sostegno 5 Tirare l altro capo del cavo sino all altro punto di fissaggio Tendere il cavo facendo un cappio attorno al secondo punto di sostegno posizionare il ti...

Page 5: ...odotto esplicitamente vietata e toglie ogni responsabilit di rivalsa sul costruttore 3 Un uso inappropiato o una errata applicazione del prodotto esplicitamente vietata e toglie ogni responsabilit di...

Page 6: ...altura del cable 2 Cree un lazo atando el cable corto B el que tiene dos lazos en la punta alrededor del rbol o construcci n 3 Gire los extremos del tensor de cable y bralo tanto como sea posible 4 M...

Page 7: ...point le plus lev du c ble pour la distance suivante entre les points de connexion y hauteur du point de connexion le plus bas x 18 5m 2 6m 2 75m 2 9m 3m 3 2m 15 5m 2 45m 2 6m 2 75m 2 9m 3m 12 5m 2 3...

Page 8: ...t dem kurzen Kabel B 2 Schlaufen am Ende eine Schlaufe rund um dem Baum Konstruktion 3 Drehen Sie am Ende des Kabelspanners sodass dieser gr tm glich offen steht 4 Befestigen Sie den Kabelspanner an d...

Reviews: