Garrison 043-5494-2 Instruction Manual Download Page 9

OPERATING INSTRUCTIONS

7

Operating Instructions

-    Press the  "MODE" button until the  "COOL"

indicator light comes on.

-    Press the ADJUST buttons "

" or "    " to

select your desired room temperature. The
temperature can be set within a range of

-    Press the "FAN"  button to choose the fan speed.

O

O

O

O

-    Press the  "MODE" button until the

"DRY" indicator light comes on.

COOL operation

fan speed. The temperature cannot be
adjusted.

FAN operation

TIMER operation

ding on what temperature you have
selected and the room temperature.

-    When the unit is on, first  press the

indicator light illuminates. It indi-
cates the Auto Stop program is
initiated.Press the Timer button

-    Press or hold the UP or DOWN

button to change the Auto time by
0.5 hour increments, up to 10 hours,
then at 1 hour increments up to 24
hours. The control will count down
the time remaining until start.

-

The selected time will register in 5

seconds and the system will autom-
atically revert back to display the
previous temperature setting.

- Turning the unit ON or OFF at any

time or adjusting the timer setting
to 0.0 will cancel the Auto Start/
Stop timed program.

-    When the malfunction (E1 or E2)

occurs, the Auto Start/Stop timed
program will also be cancelled.

indicator light

When the unit is off, first  press the

ator light illuminates. It indicates

When the unit.Press the Timer button

Stop program is  initiated.

-

The air conditioner will control the  room

temperature point set by you.

-    Under AUTO mode, you can not

select the fan speed.

-    Under this mode, you cannot select a

fan speed or adjust the temperature.

-    Keep windows and doors closed for

the best dehumidifying effect.

E2-

E4-

Protection codes:
P1-

Unplug the unit and plug it back in.
If error repeats, call for service.

Unplug the unit

 and plug it back in. If error repeats,
 call for service.

Bottom tray is full - Connect the
drain hose and drain the collected
water away. If error repeats, call
for service.

Error codes:
E1-

Unplug the unit and plug it back in.
If error repeats, call for service.

-    When you set the air conditioner in

AUTO mode, it will automatically select

the priority of the code display order is:

E4--E2--E1--P1.

Room temperature sensor error -

Evaporator temperature sensor error -

Remove italics error -

NOTE:

When more than one code occur,

17  C-30  C/62  F-88  F.

DRY operation

-    Do not install the duct in the window.

AUTO operation

cooling, heating (except in cooling-only models

 ), or fan only operation depen-

temperature automatically around the

-    Press the "MODE" button until the

"FAN" indicator light comes on.

-    Press the "FAN" button to choose the

-    Do nto install the duct in the window. 

TIMER button, The TIMER OFF

again, the TIMER ON
illuminates. It indicates the Auto
Start  program has been initiated.

TIMER button, The TIMER ON indic-

the Auto Start program has been initiated.

again, the TIMER OFF indicator light
illuminates. It indicates the Auto

Summary of Contents for 043-5494-2

Page 1: ...ase read Rules for Safe Operation and Instructions carefully before installing or operating your air conditioner he Manual should be kept in a safe place for handy reference Improper handling can caus...

Page 2: ...for service at all The air conditioner is not intended for use by young children or infirm persons without supervision Young children should be supervised to ensure that they do not play with the air...

Page 3: ...rol operating instructions 6 Operating instructions 7 Location 9 Window kit installation 9 Exhaust hose installation 12 Water drainage 13 Care and maintenance 14 AIR CONDITIONER FEATURES CARE AND MAIN...

Page 4: ...causing injury Releasing refrigerant into the atmosphere also damages the environment 3 Please recycle or dispose of the packaging material for product in an environmentally responsible manner 4 Never...

Page 5: ...low children to operate the unit unsupervised Do not use this product for functions other than those described in this instruction manual Never do this Energy Save Use the unit in the recommended room...

Page 6: ...eceptacle is accessible after the unit installation For your safety Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance Avoid fire hazard...

Page 7: ...Rear 6 7 8 9 10 11 Wheel Air intake Air intake 12 4 Remote signal receptor 5 5 Panel 13 Bottom tray drain outlet 8 9 12 11 6 7 13 1 2 3 5 4 10 Operation panel Horizontal louver blade Carrying handle U...

Page 8: ...3 seconds and AUTO OFF stop time program in 3 the TIMER setting in a range of 0 24hrs 2 SLEEP button 1 MODE select button 4 ON OFF button 6 FAN button TIMER button 5 7 O or F and the Auto timer setti...

Page 9: ...imer button Stop program is initiated The air conditioner will control the room temperature point set by you Under AUTO mode you can not select the fan speed Under this mode you cannot select a fan sp...

Page 10: ...s originally programmed DRY mode O O O O C 2 F C 2 F The louver can be set to the desired position manually Do not place any heavy objects or other loads on the louver doing so will cause damage to th...

Page 11: ...ir inlet or outlet of the unit Your window slider kit has been designed to fit most standard and horizontal window applications However it may be necessary for you to improvise modify some aspects of...

Page 12: ...foam seal to an appropriate length and seal the open gap between the top window sash and outer window Foam seal A adhesive type Foam seal Fig 10 Fig 11 Window kit Window stool Window kit Window stool...

Page 13: ...se the sliding sash securely against the window Foam seal Foam seal A adhesive type Fig 12 Fig 13 Fig 14 Fig 15 Window panel Foam seal 22 1 38 6 1 Cut the foam seal adhesive type to the proper length...

Page 14: ...ove CAUTION Fig 17 Fig 16 min 30CM max 120CM Fig 18 Fig 19 COOL HEAT heat pump type or FAN DRY or HEAT electrical heat type mode 1 Install the window exhaust adaptor B onto the exhaust hose as shown i...

Page 15: ...let the until the P1 symbol disappears If the error repeats call for service NOTE Be sure to reinstall the bottom drain plug before using the unit the unit beeps 8 times At this time the air conditio...

Page 16: ...ng on FAN mode for half a day in a warm room to dry the appliance inside and prevent mold forming Stop the appliance and unplug it wrap the cord and bundle it with the tape Remove the batteries from t...

Page 17: ...ed by dust Place the unit on a flat level ground if possible It is normal The ground is not level or not flat enough The sound comes from the flowing of the refrigerant inside the 15 temperature at th...

Page 18: ...INSTRUCTIONS Do not recharge batteries or dispose of them in fire AAA To protect the environment dispose of used batteries in special containers which are available at your local hardware store 16...

Page 19: ...INSTRUCTIONS AAA decrement RG51B30 CE Only Celsius Scale C for RG51B30 CE thr ree 17...

Page 20: ...8 9 10 11 SET TEMPERATURE O O display screen INSTRUCTIONS NOTE While the unit is running under mode it would be cancelled if or MODE button is pressed 18...

Page 21: ...MODE TEMP NOTE MODE TEMP controlled NOTE INSTRUCTIONS MODE NOTE 3 1 2 1 2 4 3 1 2 19...

Page 22: ...INSTRUCTIONS 20...

Page 23: ...INSTRUCTIONS 3 Wait for about 3 seconds and the digital display area will show the temperature again Now this function is activated 21...

Page 24: ...h On Stop Set setting 3 home Example Start Example Off Stop Start h Set CAUTION INSTRUCTIONS 22...

Page 25: ...23 a result from of items 6 Routine maintenance and cleaning necessary to keep the good working condition...

Page 26: ...24 Return Policy Garrison...

Reviews: