Electrical Safety requirements: 

1.

 

This product is to be installed Only in Restricted Access Areas  

 

(Dedicated Equipment Rooms, Electrical Closets, or the like). 

2.

 

DC products shall be installed with a readily accessible disconnect device in 
the building installation supply circuit to the product. 

3.

 

This product shall be provided with a maximum 10A DC Listed fuse or circuit 
breaker in the supply circuit when connected to a DC centralized source. 

4.

 

The external power supply for DC units shall be Listed, Direct Plug In power 
unit, marked Class 2, or listed ITE Power Supply, marked LPS, which has 
suitably rated output voltage (i.e. 24VDC or 48VDC) and suitable rated output 
current. 

5.

 

Use minimum 18 AWG size wiring for connection to a Centralized DC power 
source. 

6.

 

For earthing wiring, use minimum 14 AWG size wiring. 

7.

 

Product does not contain user replaceable fuses. Any internal fuses can ONLY 
be replaced by GarrettCom personnel through the RMA process. 

 

Installation requirements: 

1. 

Elevated Operating Ambient Temperature- If installed in a closed or multi-unit 
rack assembly, the operation ambient temperature of the rack environment may 
be greater than room ambient. Therefore, consideration should be given to 
installing the equipment in an environment compatible with the manufacturer’s 
maximum rated ambient temperature (Tmra). 

2. 

Reduced Air Flow – Installation of the equipment in a rack should be such that 
the amount of air flow required for safe operation of the equipment is not 
compromised. 

3. 

Mechanical Loading – Mounting of the equipment in the rack should be such 
that a hazardous condition is not achieved due to uneven mechanical loading. 

4. 

Circuit Overloading – consideration should be given to the connection of the 
equipment to the supply circuit and the effect that overloading of circuits might 
have on over current protection and supply wiring. Appropriate consideration 
of equipment nameplate ratings should be used when addressing this concern. 

5. 

Reliable Earthing – Reliable earthing of rack mounted equipment should be 
maintained. Particular attention should be given to supply connection other 
than direction connections to the branch circuit (i.e. use of power strip etc…) 

Summary of Contents for Quad

Page 1: ...www GarrettCom com Magnum Quad Series Fiber Switches Installation and User Guide 5 00 USD...

Page 2: ...oration NEBS is a trademark of Telcordia Technologies UL is a registered trademark of Underwriters Laboratories Important The Magnum Quad Series Fiber Switch contains no user serviceable parts Attempt...

Page 3: ...iate frequency energy and if not installed and used properly that is in strict accordance with the manufacturer s instructions may cause interference to radio communication It has been tested and foun...

Page 4: ...cess Installation requirements 1 Elevated Operating Ambient Temperature If installed in a closed or multi unit rack assembly the operation ambient temperature of the rack environment may be greater th...

Page 5: ...t Pair RJ 45 CAT3 CAT5 Unsh or Shiel 17 3 3 Table Top or Shelf Mounting 17 3 3 1 Wall or Vertical Surface Mounting 8 port QS580 18 3 3 2 Rack mounting models QS5108 and QS5116 18 3 4 RJ 45 ports int j...

Page 6: ...41 6 0 TROUBLESHOOTING 42 6 1 Before Calling for Assistance 42 6 2 When Calling for Assistance 43 6 3 Return Material Authorization RMA Procedure 43 6 4 Shipping and Packaging Information 44 APPENDIX...

Page 7: ...net Switches for temperature uncontrolled applications 6 10 100 and 2 100Mb fiber ports managed and unmanaged models all fiber types Mixed Media Fiber Hub 16 port Stackable 10 100 auto sensing Dual Sp...

Page 8: ...gths Unshielded twisted pair 100 m 328 ft Shielded twisted pair 150 m 492 ft 10BASE FL multi mode fiber optic 2 km 6 562 ft 10BASE FL single mode fiber optic 10 km 32 810 ft Maximum Standard Fast Ethe...

Page 9: ...r rack mounting Dimensions 1 75 in H x 17 0 in W x 9 13 in D 10 0 in W for QS580 4 45cm H x 43 2cm W x 23 2cm D 25 4 cm W for QS580 Weight 4 0 lb 1 8 Kg for rack mount models 2 5 lb for table top Cool...

Page 10: ...es Switches with four 100Mbps multi mode FX SC connectors QPM MST Fiber module for Quad Series Switches with four 100Mbps multi mode FX ST connectors QPM SSC Fiber module for Quad Series Switches with...

Page 11: ...VAC only 1 Set of two wall mounting brackets for QS580 Model only 1 Set of metal Ears for optional 19 rack mounting for QS5108 QS5116 only 1 Installation and User Guide this manual 1 Product Registrat...

Page 12: ...16 models each with a configuration of four port modules Quad port Modules for fiber types and for copper as well as 3 1 combo 3 RJ 45 and 1 fiber port modules The Quad port Modules can be configured...

Page 13: ...on the front panel with the IEC standard AC power connector and a manual ON OFF power switch located at the rear Fan driven cooling air flows left to right Figure 2 2 1b Rear view Magnum table top ra...

Page 14: ...al jumper setting See Section 3 4 for the flexibility to adapt to any type of Fast Ethernet devices On Magnum fiber QPMs there are three LED s per fiber port The Link LK LED indicates ready for operat...

Page 15: ...ctivity on that port when lit The 10 100 LED indicates operation at 100Mb speed when ON and at 10 Mb speed when OFF when auto negotiation is not disabled The FDX HDX LED is ON to indicate full duplex...

Page 16: ...es such as cut through or express impose minimal frame latency they will also permit bad frames to propagate out to the Ethernet segments connected The cut through technique permits collision fragment...

Page 17: ...et buffering and processing resumes This flow control sequence occurs in a small fraction of a second and is transparent to an observer See Section 4 6 for additional details Another feature implement...

Page 18: ...port module types can be configured in the same unit adapting the Quad Series Switches to varying quantities and types of fiber vs copper media Port module changes can even be done in the field Full...

Page 19: ...10 100Mb traffic domains for increased performance It can segment 10 Mbps and 100Mbps units hubs and servers in the existing network into multiple domains providing greatly increased bandwidth In thi...

Page 20: ...ule The QPM provides a switched port for two local high speed servers another for the router another for the users connecting into a 16 port dual speed hub such as the Magnum DS8016 Since 100Mb fiber...

Page 21: ...ad port fiber QPM is selected to provide 4 of the required fiber ports and two combo 3 RJ 45 1 fiber QPMs are configured for the other 2 fiber ports plus 6 of the switched copper ports Finally an RJ 4...

Page 22: ...size of the 8 port QS580 unit allows it to be easily placed in an office or lab area and it can also be either shelf of wall mounted see Section 3 3 1 below Locate an AC receptacle that is within six...

Page 23: ...e certain the connectors are clean before connecting Note One strand of the duplex fiber optic cable is coded using color bands at regular intervals you must use the color coded strand on the associat...

Page 24: ...ports CAT 3 may be used In either case the maximum distance for unshielded twisted pair cabling is 100 meters 328 ft Media IEEE Standard Connector Twisted Pair CAT 3 4 5 10BASE T RJ 45 Twisted Pair CA...

Page 25: ...extend slightly below the base of the unit to allow clearance for the rubber feet and for cooling fan exhaust space Figure 3 1 Magnum QS580 metal mounting brackets 3 3 2 Rack mounting models QS5108 an...

Page 26: ...Magnum QS5116 PWR 100 10 FDX HDX LK ACT 100 10 2 3 1 FDX HDX 4 LK 100 10 2 3 1 FDX HDX 4 ACT LK ACT ACT Fiber Switch ACT 2 3 1 4 LK FDX HDX Magnum QS5116 The 23 brackets and ETSI brackets are also av...

Page 27: ...s and most Media Converters Therefore the default setting of auto negotiation copper ports is generally desirable because it is widely used and allows for the connection of various devices without re...

Page 28: ...uad ports to be fixed even if the attached device may or may not support full duplex This is desirable when there are unknown devices presently or potentially connected which will not operate correctl...

Page 29: ...ion on RJ 45 and FDX on fiber port works well under most circumstances but cannot always be depended upon to work as expected If full duplex will not function properly in your setup internal jumpers a...

Page 30: ...ull Duplex at all ports The factory default setting is for half duplex on all fiber 10Mbps ports which is generally popular HDX works well under most circumstances If half duplex on 10Mbps will not fu...

Page 31: ...3 4 Figure 3 7 10Mbps Fiber ports internal jumper settings Note Be certain that the main power is disconnected before opening the unit or changing any internal jumper settings 3 8 Powering the Magnum...

Page 32: ...d from the factory with all required QPM modules installed There may be situations where QPM cards need to be added or replaced In cases where additional QPM cards are needed the face plate for an ava...

Page 33: ...ed the interior of the unit is exposed Figure 3 9 1a Removing Chassis Cover Caution Be careful not to disturb the power supply Looking down into the Magnum Q Series unit notice that there are individu...

Page 34: ...ow these steps to install a QPM Step 1 Remove top chassis cover See procedure in Section 3 9 1 above Step 2 Screw down tightly the two 7 16 stand off on the top of pre installed stand off from the fac...

Page 35: ...secure the module rear part and 4 40 Flat Head Black color retaining screws for front panel NOTE If a QPM is difficult to install try it in another port slot Some of the port modules may fit easily in...

Page 36: ...Figure 3 9 3a Remove the front screws first and then screw mounted on the rear top of the QPM to be removed Figure 3 9 3a Front View Face Plate QPM Retaining Screws Step 3 Remove QPM Card Gently pull...

Page 37: ...functions of both are described below Filtering and Forwarding Each time a packet arrives on one of the switched ports the decision is taken to either filter or to forward the packet Packets whose so...

Page 38: ...node push in or to be cascaded push out to a 10 100Mb repeater or switching hub in the network Verify proper Up link push button position by noting Port 1 s LK link LED status which is illuminated whe...

Page 39: ...depending on network changes that may occur If the device at the other end is not an auto negotiating device the Quad Switch s RJ 45 ports will try to detect its idle signal to determine 10 or 100 spe...

Page 40: ...if a long burst of activity causes the switch to save frames until its buffer memory is full This is most likely to occur when data is moving from a 100Mb port to a 10 Mb port and the speed difference...

Page 41: ...r Port Module Speed Std Mode Std km fdx hdx Wave length nm Cable Size m X mitr Output PT dB R cvr Sens PR dB Worst OPB dB Worst distance Km fdx typical OPB dB typical distance Km fdx QPM10 FST 10 Mb F...

Page 42: ...ons with illustrations Remove the QPM s from the shipping container Be sure to keep the shipping container should you need to ship any of the QPMs separately at a later date In the event there are ite...

Page 43: ...ront of the module identifies it as 100 FX to avoid confusion with other similar looking 10 Mb fiber QPMs 5 2 1a QPM10 MST 10 Mbps multi mode FL ST Quad port type twist lock The Magnum QPM10 MST is a...

Page 44: ...tions as a fiber optic transceiver to the Quad Switches supporting four single mode fiber network segments The QPM SSC when installed in a Magnum Quad Series Fiber Switch operating at 100Mbps full dup...

Page 45: ...FDX or HDX operation It has the same 100Mb FX lettering on the faceplate Note that the other end of the fiber cable may have a different connector not necessarily an MT RJ type 5 2 5 QPM MV45 100Mbps...

Page 46: ...minimize emissions and will allow both unshielded twisted pair UTP and shielded twisted pair STP cable connections The QPM RJ45 quad port module is equipped with a Media Dependent Interface Crossover...

Page 47: ...ons as a fiber optic transceiver to support 100BASE FX network segments When installed in a Quad Series Fiber Switch it supports fiber cable distances up the IEEE standard 100Mbps distance limits i e...

Page 48: ...o quad port module It is the same as the QPRJ MSC 3 1 combo module except the fiber port is single mode See Section 5 2 3 for a description of the 100Mb single mode fiber port 5 2 10 QPM FP The QPM FP...

Page 49: ...llation Section of the applicable chapter of this manual Also check to make sure that the various components of the network are interoperable 2 Check the cables and connectors to ensure that they have...

Page 50: ...inistration procedures should all be noted in this record 6 3 Return Material Authorization RMA Procedure All returns for repair must be accompanied by a Return Material Authorization RMA number To ob...

Page 51: ...ghouse Dr Fremont CA 94539 Attn Customer Service APPENDIX A WARRANTY INFORMATION GarrettCom Inc warrants its products to be free from defects in materials and workmanship for a period of three 3 years...

Page 52: ...polarity connection for example will neither affect the Quad Series Switches its internal power supply nor will it blow the fuse in the internal power supply The manual power On Off Switch optional is...

Page 53: ...o the Magnum unit beginning with ground Ensure that each lead is securely tightened Note The GND should be hooked up first The Quad Series Switch unit has a floating ground so the user may elect to Gr...

Page 54: ...itch chassis Input Two separate sources each at 20 36 VDC Power Consumption Model QS5108 QS5116 30 watt typical 50 watts max Power Supply Internal 100 and 125VDC Dual Source model Dual Src1xxV DC Powe...

Page 55: ...ut is absent or even if it is connected with reverse polarity or shorted or grounded d Reverse polarity connections if they should accidentally occur on either input will not damage the switch or powe...

Page 56: ...alized DC power source 2 Fastening torque of the lugs on the terminal block 9 inch pound max 3 Centralized DC Power Source cable securement use at least four cable ties to secure the cable to the rack...

Reviews: