Magnum Quad-Series Fiber Switches
Installation and User Guide (06/09)
16
www GarrettCom com
.
.
of the QPMs.
The various media types supported along with the corresponding IEEE
802.3 and 802.3u standards and connector types are as follows:
IEEE Standard Media Type Max. Distance Port Module
Fiber:
100BASE-FX
m
m
1
Fiber
2.0km (6,562 ft)
QPM-MSC,
-MST
sgl.m
2
Fiber
18.0km (95K ft) QPM-SSC
small form factor
m
m
1
Fiber
2.0km (6,562 ft)
QPM-MTRJ,
-MV45
10BASE-FL
m
m
1
Fiber
2.0km(6,562 ft)
QPM10-FST
Copper:
10BASE-T & 100BASE-TX twisted pair 100m (328 ft)
QPM-RJ45
1
mm = multi-mode
2
sgl.m = single-mode
3.2.1
Connecting Fiber Optic ST-type, “twist-lock”
The following procedure applies to installations using a QPM with ST-type fiber
connectors. This procedure applies to ports using a QPM-MST or QPM10-MST.
1.
Before connecting the fiber optic cable, remove the protective dust caps from the
tips of the connectors on the QPM. Save these dust caps for future use.
2.
Wipe clean the ends of the dual connectors with a soft cloth or lint-free lens tissue
dampened in alcohol. Make certain the connectors are clean before connecting.
Note:
One strand of the duplex fiber optic cable is coded using color
bands at regular intervals; you must use the color-coded strand on the
associated ports at each end of the fiber optic segment.
3.
Connect the Transmit (TX) port (light colored post) on the Magnum QPM to the
Receive (RX) port of the remote device. Begin with the color-coded strand of
the cable for this first TX-to-RX connection.
4.
Connect the Receive (RX) port (dark colored post on the PM) to the Transmit
(TX) port of the remote device. Use the non-color coded fiber strand for this.
5.
The LINK LED on the front of the QPM will illuminate when a proper
connection has been established at both ends (and when power is ON in the unit).
If LINK is not lit after cable connection, the normal cause is improper cable
polarity. Swap the fiber cables at the QPM connector to remedy this situation.
3.2.2
Connecting Fiber Optic SC-type, "Snap-In"
The following procedure applies to installations using a QPM with SC-type
fiber connectors, i.e., using QPM-MSC, QPM-SSC single-mode, and QPM10-MSC.
When connecting fiber media to SC connectors, simply snap on the two square
male connectors into the SC female jacks of the QPM until it clicks and secures.