11.5.1
INSTALLATION
• With power disconnected locate archway and console in their desired locations;
•
Locate connecting wire and protect from tampering or vandalism, as necessary;
•
Plug the wire into the rear of the console;
•
Open the Access Door of the detection unit;
•
Remove three (3) screws that hold the controller cover;
• Plug the wire into the Circuit Board connector as shown on Page 27;
•
Replace covers and connect to power.
11.6
BATTERY BACK-UP MODULE (OPTIONAL)
This optional module is a field-installable assembly that provides power to operate the MT 5500
for up to twenty (20) hours on a fully charged battery. System software includes an alarm feature
that alerts the operator to a low-battery condition. This ensures that the unit continues to operate
at its peak performance level.
This module includes two 12v batteries and charging circuitry that comprise the Optional Battery
Pack. This module has a battery-monitoring circuit which will charge the battery within 12 hours
and will switch to trickle-charge to maintain a fully charged condition without damaging the batter-
ies.
11.6.1
INSTALLATION
1. Open the access door of the detection unit;
2. Disconnect the AC power plug from the Power Supply Module;
3. Remove the three (3) screws that hold the Controller Module Cover;
4. Remove the four (4) acorn nuts that are attached to the Battery Pack Module mounting studs;
5. Install the Battery Pack Module and replace the acorn nuts;
6. Disconnect the Power Supply Module connector on the upper left of the Controller Circuit
Board;
MT 5500
User Manual
©2006 GARRETT METAL DETECTORS 43
PN 1530200.F.0506