Troubleshooting
Indication
Type of error
Action
Red solid light
Residual current device or residual
current circuit breaker with over cur-
rent protection has tripped
Reset, see section: Resetting the residual cur-
rent device or residual current circuit breaker
with over current protection
Red flashing light Malfunctioning connector
Contact a qualified electrician
Yellow solid light
Inappropriate cable
Check that the correct type of cable is used. A
16A cable cannot be used in a 32A charger
Yellow flashing light Engine lock socket is not in the locked
position
Contact a qualified electrician
No indication
Check the feeding fuse
If the prescribed actions do not help, contact a qualified electrician.
Technical data
Specifikations
Standards/directives:
IEC 61851-1, 61851-22 och IEC TS 61439-7
Assembly:
Only wall mounting
Rated voltage:
230V/400V 50Hz
Installation system:
TT, TN and IT system. (S-marked for TT & TN system)
Charging type:
Mode 3
Enclosure class:
IP44
Mechanical impact resistance: IK08
Operating temperature:
-25˚C - +40 ˚C
Assembly height
0.5-1.5 metres floor/ground to the lower edge of the charger
Weight:
Approximately 3 kg with socket
3,8-4,1 kg with cable and connectors, 1-phase
5,4 kg with cable and connectors, 3-phase