PARTS LIST MODEL HD-2 

Part Number 

Description 

1500-045 

Capacitor, 6800uf 550VDC 

2600-016 

Fan, 115V 50/60Hz 3.625” sq x 1” 

2600-017 

Filter Assy, HD-2 

2600-018 

Finger guard 

2825-029 

Feet, Rubber 

320-0007 

Rectifier, bridge 35A 

356-0001 

SS Relay, 240VAC 40A 

3700-002 

Sensor, reflective 

3700-006 

Display, 2x16 LCD 

375-0049 

Thermostat, OP 210F 

398-0073 

Power cord set, 10A 120V 

4075-289 

Manual, operation 

4300-033 

Fuse, 3.15A 250V 

4300-034 

Fuse, 1.6A 250V 

4300-025 

Fuse holder, 5 x 20mm 

4800-009 

Thyristor Module 

4800-028 

Diode module, 600V100A 

5100-034 

Switch, power rocker 

5600-025 

Transformer, HD-2 series 

SA1400-347 

Assy, Chassis Base 

SA1400-349 

Assy, Coil Clamp 

SA1700-204G 

PCB Assy, SS Controller 

SA1800-103 

Coil Assy, 160W 

SA1400-350 

Assy, Media Drawer 

SA3700-006B 

Assy, door sensor 

SA6000-174 

Harness, Main 

 

 

 

 

 

 

 

 

 

Summary of Contents for HD-2 Series

Page 1: ...tallation Manual HD 2 Series Continuous Degaussing System Operation and Installation Manual www GarnerProducts com 800 624 1903 10620 Industrial Ave Suite 100 Roseville CA 95678 Manufactured in the U S A PN 4075 289 Rev 001 ...

Page 2: ...ection Reference 3 Input Voltage Configuration WARNING 4 Power Plug 7 Fuse Block 7 Location 7 Cooling 7 OPERATION 8 Degaussing Instructions 8 Automatic Degaussing Degaussing Instructions for DLT Media Degaussing Overview 9 Controls and Indicators 10 POWER Button RED LCD Display Media Drawer Automatic Degaussing Technical Detail 10 Error Codes 11 Charge Error Drawer Open Error Gauss Error Overheat ...

Page 3: ... also limiting the magnetic field exposure to 1 second for every 20 pieces of media degaussed Distance from degausser Magnetic field Front Panel Magnetic field Side Duration of Field 0cm 0 inches 620 gauss 328 gauss 0 05 Second 10cm 4 inches 249 gauss 81 gauss 0 05 Second 20cm 8 inches 85 gauss 26 gauss 0 05 Second 30cm 12 inches 19 gauss 8 gauss 0 05 Second Note The testing room measured 0 4 gaus...

Page 4: ...5A 240V Under Standby 0 15A While charging 2 0A At the time of ERASE 0 3A Degausser System Capacitive Discharge Operating Time Duty Cycle Continuous Erasing time 10 milliseconds Cycle time 60 seconds per cycle Magnetic Field 8 500 Oe Peak 8 300 Oe measured in center Max Media Size 108mm 4 25 in W x 38mm 1 50 in H x 149mm 5 86 in D Erasing Area Size 108mm 4 25 in W x 38mm 1 50 in H x 149mm 5 86 in ...

Page 5: ...t voltage is configured to match the voltage from the power mains the HD 2 will plug into Call Garner Products Inc if the voltage listed is not compatible with your voltage or if you have any questions International customers call 011 916 784 0200 Line Voltage Selection Reference The Line Voltage Selection Reference is a guide for configuring the voltage jumper to the correct tap of the transforme...

Page 6: ...w the steps listed below All trouble shooting and wiring checks must be performed by a qualified electrician or authorized plant personnel 1 Read the Warning labels All trouble shooting and wiring checks must be performed by a qualified electrician or authorized plant personnel 2 Remove the power cord from the back of the HD 2 3 Using a Torx T 20 driver remove 3 screws from each side and 7 screws ...

Page 7: ...internally attached Carefully place the cover next to the HD 2 as shown 5 To change the jumper position pull the brown jumper wire from the front side of the fuse block and move it to the corresponding terminal that matches the power mains outlet voltage Notice this photo shows the correct jumper setting for 120 VAC ...

Page 8: ...HD 2 Operation and Installation Manual Page 6 6 Notice this photo shows the correct jumper setting for 240 VAC 7 Replace the Top Cover and the screws ...

Page 9: ...cation The degausser must be placed on a flat hard surface Keep at least a 6 inch 15cm distance from any object that may interfere with the cooling fan exhaust located on the backside of the degausser As a general rule media not intending to be erased should be kept about 60cm 2 feet away Cooling Forced air cooling is used to maintain safe operating temperatures within the degausser The air intake...

Page 10: ... up and sliding out the drawer Step 5 Insert another hard drive or turn the power off and close the drawer Degaussing Instructions for DLT Media Remove the plastic protective cases Simply follow the degaussing instructions above for complete erasure Note For DLT media that is to be re used Although the data is completely degaussed in one operation a second pass rotated at 90 degrees is required to...

Page 11: ... version TOTAL Displays total erasing cycles Number on left indicates number of times the counter reached 50 000 Insert Media Session 0 Ready for media to be placed in the Media Drawer Counter for erase cycles from power up Step 2 Insert media Drawer Open Indicates media drawer is open this is normal when inserting media to be erased Erase Cycle Initiated Drawer has closed and the erase cycle has ...

Page 12: ...ure each erase cycle is measured to ensure the strength of the erase field is sufficient for complete erasure of data In addition the LCD will display a Field Strength Graph I of the actual erase field giving the operator real time status of the HD 2 The I in the graph represents the strength of the erase field The portion of the graph represents the normal range for field strength level The I wit...

Page 13: ...hat drawer is seated in detent Gauss Error The LCD displays GAUSS ERROR This error indicates the erasing field may not have been adequate to effectively erase the media in the degaussing chamber Action Turn off the HD 2 for approximately one minute Turning off the power to the HD 2 will clear the error Turn the HD 2 back on To initiate the degauss cycle with media already in the media drawer open ...

Page 14: ...ctive 3700 006 Display 2x16 LCD 375 0049 Thermostat OP 210F 398 0073 Power cord set 10A 120V 4075 289 Manual operation 4300 033 Fuse 3 15A 250V 4300 034 Fuse 1 6A 250V 4300 025 Fuse holder 5 x 20mm 4800 009 Thyristor Module 4800 028 Diode module 600V100A 5100 034 Switch power rocker 5600 025 Transformer HD 2 series SA1400 347 Assy Chassis Base SA1400 349 Assy Coil Clamp SA1700 204G PCB Assy SS Con...

Page 15: ...HD 2 Operation and Installation Manual Page 13 DECLARATION OF CONFORMITY ...

Page 16: ...REPLACEMENT SERVICE AS DETERMINED BY GARNER IN ITS SOLE DISCRETION No Garner dealer reseller agent or employee is authorized to make any modification extension or addition to this warranty If any term is held to be illegal or unenforceable the legality or enforceability of the remaining terms shall not be affected or impaired EXCEPT AS PROVIDED IN THIS WARRANTY AND TO THE EXTENT PERMITTED BY LAW G...

Reviews: