8
Install the new battery into the back
plate with the label side up, using the
same orientation as the old battery.
The battery orientation is noted
graphically inside the back plate.
9
Replace the battery plate to its original
position.
10
Replace and tighten the battery plate
screws.
11
With the new battery, connect the
battery connector to the device.
When properly installed, the connector
plug snaps into the port.
12
Reconnect the rotary switch connector
to the device.
When properly installed, the connector
plug snaps into the port.
13
Verify the gasket is not damaged and
is completely seated in the groove on
the front half of the device.
14
While ensuring the battery and rotary
switch wires are not pinched, hold the
back plate and the device firmly
together, and replace all eight security
screws without tightening.
15
Verify the back plate and the device
are aligned with no gaps.
16
Tighten the screws evenly.
17
Verify the gasket is not sticking out of
the device.
Pro 70 Dog Collar Device Components