background image

3

Marine Ethernet Connection

I

NSTALLATION

 I

NSTRUCTIONS

 

4.  Examine the connection removed in Step 1 and compare to the wire positions table and Figure 4. Make note which cable side, A or B, 

was removed in Step 1.

Position

Wire Color—Main/Stripe

Side A

Side B

1

White/Orange

White/Green

2

Orange

Green

3

White/Green

White/Orange

4

Blue

Blue

5

White/Blue

White/Blue

6

Green

Orange

7

White/Brown

White/Brown

8

Brown

Brown

 

NOTE: 

The Garmin Marine Network requires cross over cables not exceeding 100 meters between devices. When constructing a custom cable 

from bulk wire, you must create both a Side A and Side B.

5.  Prepare cable for plug installation according to the following steps:

a.  Using a sharp knife, insert blade between the cable shield and jacket. Slit the jacket 5/8" back from the trimmed end of the cable.
b.  Peel the jacket back and remove the slit portion.
c.  Trim the shield and Mylar fi lm away from wires. Be careful not to cut any of the wires.
d.  Fold the drain wire back over the jacket and trim to approximately 5/16" in length.
e.  Untwist the wire pairs enough to ensure a proper connection.
f.  Arrange individual wires in proper order according to the table shown above. For example, if you have identifi ed the end of the cable 

in Step 4 as Side A, arrange the wires for Side A. If you are constructing a custom cable from bulk wire, you need to make both a 

Side A and a Side B connection.

g.  Trim the wire ends to even length, leaving approximately 9/16" from the ends to the jacket edge as shown in Figure 5.
h.  Place the drain wire on the jacket as shown in Figure 5. Wrap the supplied copper tape around cable as close to the edge of the 

jacket as possible.

i.  Using a pair of pliers, squeeze copper tape to pre-form the cable jacket end for easier insertion into the plug. Use caution to avoid 

damaging the copper tape.

Figure 4

Position 1

Position 8

 

NOTE: 

The wires are arranged in twisted pairs. To minimize electronic 

interference, only untwist the wires enough to ensure a proper connection.

9/16"

Drain Wire

Figure 5

190-00489-00_0B.indd   3

3/16/2005   12:14:09 PM

Summary of Contents for Marine Network Cable Connector (RJ45, 2-pack

Page 1: ...Marine Ethernet Connection installation instructions 190 00489 00_0B indd 1 3 16 2005 12 14 06 PM...

Page 2: ...e misuse accident or unauthorized alteration or repairs THE WARRANTIES AND REMEDIES CONTAINED HEREIN ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED OR STATUTORY INCLUDING ANY LIA...

Page 3: ...ation you need the appropriate equipment and tools If you experience dif culty with the installation contact Garmin Product Support Included Equipment 1 RJ 45 Modular Plug 1 Ethernet cable termination...

Page 4: ...connection for Step 4 2 Remove strain relief nut from cable connection housing and slide onto cut end of the cable as shown in Figure 2 Strain Relief Cut End of Cable Figure 2 3 Feed the cable end thr...

Page 5: ...any of the wires d Fold the drain wire back over the jacket and trim to approximately 5 16 in length e Untwist the wire pairs enough to ensure a proper connection f Arrange individual wires in proper...

Page 6: ...wires Figure 6 7 Using AMP Modular Plug Hand Tool and Die Set or compatible equivalent crimp the plug onto wires following the crimp tool manufacturer s recommended procedure 8 After the plug is crim...

Page 7: ...elief nut onto the housing and tighten snugly with a 15 mm wrench Be careful not to over tighten the nut Figure 9 10 Install the O ring onto the housing as shown in Figure 10 The cable is now ready fo...

Page 8: ...151st Street Olathe Kansas 66062 U S A Garmin Europe Ltd Unit 5 The Quadrangle Abbey Park Industrial Estate Romsey SO51 9DL U K Garmin Corporation No 68 Jangshu 2nd Road Shijr Taipei County Taiwan www...