70
GTN 725/750 Cockpit Reference Guide
190-01007-04 Rev. K
Messages
Message
Description
Action
CROSSFILL
ERROR -
GTN
Navigation DB
mismatch. See
CRG for crossfilled
items.
The navigation
databases do not
match between GTNs
resulting in a loss
of communication
between two units.
Check the specified database
version of both GTNs and ensure it
is up-to-date. Update the specified
database if needed.
CROSSFILL
ERROR -
GTN software
mismatch. See
CRG for crossfilled
items.
Crossfill is configured
“on” but is not working
due to software
mismatch.
See Pilot’s Guide for a list of
crossfilled items that will no longer
be crossfilled. Contact dealer to
have software versions updated.
CROSSFILL
STATUS -
Crossfill
is turned off.
Crossfill is turned off.
No action.
DATABASE -
A procedure has
been modified in
a cataloged flight
plan.
A new database update
caused a procedure to
be truncated because
the flight plan now has
too many waypoints or
removed a procedure
because it no longer
exists in the database.
Verify stored cataloged flight plans
and procedures. Modify stored
flight plans and procedures as
necessary to include the current
procedures by re-loading those
procedures to the stored flight plan
routes.
DATABASE -
Chart database
valid until [DATE].
The GTN is configured
for ChartView or
FliteCharts and the
chart database has or is
about to expire.
Verify chart database expiration
date on the System – System
Status page. Update chart
database if necessary for
operations.
DATABASE -
Chart function
unavailable.
The GTN is configured
for ChartView or
FliteCharts and chart
verification has failed.
Contact dealer for service.