Post-Installation Configuration & Checkout
GNS 480 (CNX80) Installation Manual560-0982-01 Rev A
3-7
Figure 3-6 - Altimeter Interface
When a baro potentiometer is installed, calibrate it as follows:
1.
Press the
CAL
line select key. The calibration page shown in Figure 3-7 will then be displayed. If
the
CAL
line select key is pressed when the baro pot is set to NOT INSTALLED, it will
automatically be changed to INSTALLED.
2.
Follow the instructions on the display for calibrating the baro potentiometer. If the GNS 480 will not
accept the calibration when the
MENU/ENTER
key is pressed, there may be a problem with the baro
potentiometer interface.
NOTE
The accuracy of the system is dependent on this calibration. Do not rush this step.
3.
After successfully calibrating the baro potentiometer a green CALIBRATION PASSED message will
be displayed. After this message appears, rotate the baro potentiometer and ensure that the
CURRENT BARO value being displayed is within
±
0.03 "Hg (±1 mB) of the actual altimeter setting.
Figure 3-7 - Baro-Altimeter Calibration
Summary of Contents for GNS 480
Page 1: ...GNS 480 CNX80 Color GPS Nav Com Installation Manual September 2004 560 0982 01 Rev A...
Page 10: ...Table of Contents viii 560 0982 01 Rev A GNS 480 CNX80 Installation Manual NOTES...
Page 30: ...General Information 1 20 560 0982 01 Rev A GNS 480 CNX80 Installation Manual NOTES...
Page 126: ...Periodic Maintenance 6 2 560 0982 01 Rev A GNS 480 CNX80 Installation Manual NOTES...
Page 150: ...Appendix D Interconnect Diagrams D 2 560 0982 01 Rev A GNS 480 CNX80 Installation Manual NOTES...
Page 185: ......
Page 186: ......