4.4.2.4 Superflags
Pin Name
Connector
Pin
I/O
MAIN LATERAL SUPERFLAG
P4001
17
Out
MAIN VERTICAL SUPERFLAG
P4001
18
Out
The output supplies not less than 500 mA on a 28 volt system and 250 mA on a 14 volt system with the
output voltage not less than (AIRCRAFT POWER –1.5 VDC) when the flag is to be OUT OF VIEW.
The output voltage with respect to ground is less than 0.25 VDC when the flag is to be IN VIEW.
4.4.2.5 OBS
Pin Name
Connector
Pin
I/O
MAIN OBS ROTOR C
P4001
31
Out
MAIN OBS ROTOR H (GROUND)
P4001
32
Out
MAIN OBS STATOR D
P4001
33
In
MAIN OBS STATOR E (2.5V COMMON OBS)
P4001
34
Out
MAIN OBS STATOR F
P4001
35
In
MAIN OBS STATOR G (2.5V COMMON OBS)
P4001
36
Out
MAIN OBS ROTOR C and H are a buffered output that is intended to drive the OBS rotors. MAIN OBS
STATOR D and MAIN OBS STATOR F are each phase and amplitude shifted version of the MAIN
ROTOR C output. Each pair is intended to read one of the two windings of the indicator’s OBS stator.
4.4.3
Main Indicator Configuration
None.
4.4.4
Main Indicator Calibration and Checkout
Refer to Section 5.3.11 for the main CDI/OBS checkout.
4.4.5
Main Indicator Interconnect
Refer to Figure H-7 for the generic main indicator interconnect. Refer to Figure H-8 for the interconnect
between a GNS 430W and a Bendix/King KI 209A. Refer to Figure H-9 for the interconnect between a
GPS 400W or GNC 420W and a Bendix/King KI 208A.
Summary of Contents for GNC 420AW
Page 2: ...400W Series Installation Manual 190 00356 02 Rev G ...
Page 149: ...400W Series Installation Manual Page C 1 190 00356 02 Rev G Appendix C RESERVED ...
Page 206: ...Page H 30 400W Series Installation Manual Rev G 190 00356 02 Figure H 17 GTX 330 Interconnect ...
Page 212: ...Page H 36 400W Series Installation Manual Rev G 190 00356 02 Figure H 21 RMI OBI Interconnect ...
Page 235: ......
Page 236: ......