background image

Installation 

 

560-1057-00 Rev A

 

GDL 90 Capstone Upgrade Instructions 

2-4 

 
 

2.5 E

LECTRICAL 

C

ONNECTIONS

 

The GDL 90 Capstone Upgrade Installation Kit includes the adapter cable and three coax connectors. 
The connector layouts are shown in Figure 2-6. The D-sub connectors use the supplied crimp contacts as 
specified in Table 2-2. Make the crimp connections with the crimp tool specified

.

  

 

Table 2-2 - Interface Connectors 

Figure 2-6

 

Connector Crimp 

Contact 

Ref. Description 

P/N 

Description 

P/N 

Description 

P1 

Main System 

162-1575  15 Pin D-Sub Receptacle 

245-0027  20-24 AWG socket contact 

P2 

I/O 

162-1577  37 Pin D-Sub Receptacle 

245-0027  20-24 AWG socket contact 

n/a 

Maint. Port 

162-1574  9 Pin D-Sub Receptacle 

245-0027  20-24 AWG socket contact 

P3 

GPS antenna 

162-0043  Coax connector, right angle 

N/A 

N/A 

P4 

UAT ant (top) 

162-0043  Coax connector, right angle 

N/A 

N/A 

P5 

UAT ant (bot) 

162-0043  Coax connector, right angle 

N/A 

N/A 

 
The following table shows the specifications for the crimp contacts. Alternate crimp contact part 
numbers may be used that are equivalent to those specified in the table below.  
 

Table 2-3 - Crimp Contact Specifications 

Garmin AT Part Number 

245-0027 

Description 

20-24 AWG crimp socket contact 

Color bands 

Orange/Blue/Gray 

ITT/Cannon P/N 

031-1007-042 

Military number 

M39029/63-368 

 
 

2.5.1 C

ABLING AND 

W

IRING

 

2.5.1.1 Adapter 

Cable 

An adapter cable is provided with the GDL 90 Upgrade Installation Kit. Install the adapter cable as 
follows: 

 

Mount the DB15 and DB37 connectors of the cable to the mounting tray backplate 

 

Connect the DB37 connector of the adapter cable to the DB37 connector of the existing wiring. 
Fasten with 2 screws (provided.) 

 

Attach cable ground lug to one of the holes on the side rail of backplate with a #4 screw 

 

2.5.1.2 

APM and Maintenance Connector 

Connect the micro APM to the DB15 connector of the adapter cable using crimp socket contacts 
(provided).  The APM may be fastened to the backplate of the tray close to the 37-pin connector using 
cable ties through holes on the backplate.  Refer to Figure 2-3 for more details.  APM wiring must be 4 
inches maximum length. 
 
Connect the DB9 Maintenance PC connector to the DB15 connector of the adapter cable using crimp 
socket contacts (provided) and 3-conductor wire.  The Maintenance DB9 connector should be secured 

Summary of Contents for GDL 90 UAT

Page 1: ...GDL 90 UAT Data Link Sensor Capstone Upgrade Instructions April 2004 560 1057 00 Rev A...

Page 2: ...produced copied transmitted disseminated downloaded or stored in any storage medium for any purpose without the express written permission of Garmin Garmin hereby grants permission to download a singl...

Page 3: ...washer to install kit update APM p n Table 1 2 Add tray side view Figure 2 2 APM wiring 4 inches maximum 2 5 1 2 Add transmitter caution statement 2 5 1 3 ORDERING INFORMATION To receive additional co...

Page 4: ...ii GDL 90 Capstone Upgrade Instructions List of Effective Pages Page Rev Page Rev Page Rev Page Rev Page Rev Cover A Copyright i A ii A iii iv 1 1 1 2 A 2 1 2 2 2 3 A 2 4 A 2 5 A 2 6 A 2 7 2 8...

Page 5: ...ELECTRICAL CONNECTIONS 2 4 2 5 1 CABLING AND WIRING 2 4 2 5 2 INTERFACE CONNECTOR DEFINITION 2 8 LIST OF TABLES TABLE 1 1 PACKAGE CONTENTS 1 2 TABLE 1 2 INSTALLATION KIT CONTENTS PN 424 6081 150 1 2...

Page 6: ...Table of Contents iv 560 1057 00 GDL 90 Capstone Upgrade Instructions NOTES...

Page 7: ...60 1049 xx which is included in the GDL 90 Product CD The information in this manual is STC approved Only the equipment interfaces covered in this manual are within the scope of this STC Refer to the...

Page 8: ...ail 430 6081 1xx xxx 1 GDL 90 UAT Data Link Sensor 140 0063 xx 1 GDL 90 Product CD 560 1057 xx 1 GDL 90 Capstone Upgrade Instructions Table 1 2 Installation Kit Contents PN 424 6081 150 Part Qty Descr...

Page 9: ...e aircraft prior to starting modification to ensure aircraft has the ability to carry the GDL 90 load Document the results of the electrical load analysis on FAA Form 337 2 2 MATERIALS NOT SUPPLIED 2...

Page 10: ...four 8 32 pan head screws Refer to Figure 2 1 and Figure 2 2 for the GDL 90 adapter plate and mounting tray dimensions After the adapter cable is installed to the mounting tray back plate route wiring...

Page 11: ...Installation GDL 90 Capstone Upgrade Instructions 560 1057 00 Rev A 2 3 Figure 2 2 GDL 90 Mounting Tray...

Page 12: ...quivalent to those specified in the table below Table 2 3 Crimp Contact Specifications Garmin AT Part Number 245 0027 Description 20 24 AWG crimp socket contact Color bands Orange Blue Gray ITT Cannon...

Page 13: ...are 3 wiring options as depicted in Figure 2 4 GPS signal connection to the MX20 shall be disconnected and rerouted to the GDL 90 If only one GPS antenna is installed a signal splitter may be used to...

Page 14: ...from Garmin AT If a VHF comm transmitter causes problems with the GPS on the selected frequencies as listed in the post installation checkout the problem may be due to the ELT This can be verified by...

Page 15: ...Conductor Solder cap into place 2 Places Shrink tube as shown Solder Cap 2 Places STEP 2 125 Shield 0 250 Flare Outer Shield as Shown Solder Outer Shield to Connector Place cable in connector as show...

Page 16: ...Installation 560 1057 00 Rev A GDL 90 Capstone Upgrade Instructions 2 8 2 5 2 INTERFACE CONNECTOR DEFINITION Figure 2 6 Rear Connector Layout...

Page 17: ......

Page 18: ......

Reviews: