background image

Single-Gas: This mode allows

you to dive with a single

gas blend. You can set up

to 11 additional gases as

backup gases.

Multi-Gas: This mode allows

you to configure multiple

gas blends and switch

gases during your dive.

You can set the oxygen

content from 5–100%.

This mode supports one

bottom gas, and up to 11

additional gases as

decompression or backup

gases.
NOTE: Backup gases are

not used in no-

decompression limit (NDL)

and time to surface (TTS)

decompression

calculations until you

activate them during a

dive.

CCR: This mode for closed-

circuit rebreather (CCR)

diving allows you to

configure two partial

pressure of oxygen (PO2)

setpoints, closed-circuit

(CC) diluent gases, and

open-circuit (OC)

decompression and

backup gases.

Gauge: This mode allows you

to dive with basic bottom

timer features.
NOTE: After diving in

gauge mode, the device

can only be used in gauge

Quick Start Manual

11

EN

Summary of Contents for A04272

Page 1: ......

Page 2: ...Quick Start Manual 4 Manuel de démarrage rapide 19 Manuale di avvio rapido 37 Schnellstartanleitung 53 Guía de inicio rápido 71 Manual de início rápido 88 ...

Page 3: ...arks of Garmin Ltd or its subsidiaries These trademarks may not be used without the express permission of Garmin The BLUETOOTH word mark and logos are owned by the Bluetooth SIG Inc and any use of such marks by Garmin is under license Other trademarks and trade names are those of their respective owners El número de registro COFETEL FETEL puede ser revisado en el manual a través de la siguiente pá...

Page 4: ......

Page 5: ......

Page 6: ......

Page 7: ...ith your smartphone 3 Follow the instructions in the app to complete the pairing and setup process Using the Watch Hold LIGHT to view the controls menu The controls menu provides quick access to frequently used functions such as turning on do not disturb mode turning on the battery saver feature and turning the watch off From the watch face press UP or DOWN to scroll through the glance loop Your w...

Page 8: ......

Page 9: ...main well within the limits provided by this device to minimize the risk of DCS You should consult a physician regarding your fitness before diving Perform pre dive safety checks such as checking proper device function and settings display function battery level tank pressure and bubble checks to check hoses for leaks Do not dive with a gas if you have not personally verified its contents and inpu...

Page 10: ......

Page 11: ...on or backup gases NOTE Backup gases are not used in no decompression limit NDL and time to surface TTS decompression calculations until you activate them during a dive CCR This mode for closed circuit rebreather CCR diving allows you to configure two partial pressure of oxygen PO2 setpoints closed circuit CC diluent gases and open circuit OC decompression and backup gases Gauge This mode allows y...

Page 12: ...tones Dive Setup You can customize the dive settings based on your needs Not all settings are applicable for all dive modes You can also edit the settings before you start a dive Hold MENU and select Dive Setup See the owner s manual for more information Starting a Dive 1 From the watch face press START 2 Select a dive mode page 10 3 If necessary press UP to edit the dive settings such as the gase...

Page 13: ...DOWN to scroll through the data screens and dive compass Press START to view the in dive menu When you ascend to 1 m 3 3 ft the End Dive Delay timer begins counting down When the timer elapses the device automatically ends and saves the dive You should keep your wrist out of the water while the device saves your dive exit location Viewing the Dive Log Glance The glance displays summaries of your r...

Page 14: ...its OTU and central nervous system CNS percentage NOTE The OTU accumulated during a dive expire after 24 hours 3 Press DOWN to view your tissue load details Device Information Wearing the Device Wear the device above your wrist bone NOTE The device should be snug but comfortable For more accurate heart rate readings the device should not move while running or exercising For pulse oximeter readings...

Page 15: ......

Page 16: ......

Page 17: ...ch will charge faster when exposed to sunlight because the solar charging lens is optimized for the spectrum of sunlight For maximum battery performance charge the watch in bright sunlight NOTE The watch protects itself from overheating and stops charging automatically if the internal temperature exceeds the solar charging temperature thresholdpage 18 NOTE The watch does not solar charge when conn...

Page 18: ...frequency 2 4 GHz X dBm maximum Depth sensor Accurate from 0 m to 100 m 0 ft to 328 ft complying with EN 13319 Resolution m 0 1 m until 99 9 m 1 m at 100 m Resolution ft 1 ft Inspection interval Inspect parts before each use for damage Replace parts as needed 1 Troubleshooting Restarting Your Device 1 Hold LIGHT until the device turns off 2 Hold LIGHT to turn on the device 1 Aside from normal wear...

Page 19: ......

Page 20: ......

Reviews: