![Garland XPE12 Service Manual Download Page 76](http://html1.mh-extra.com/html/garland/xpe12/xpe12_service-manual_564395076.webp)
76
Document: GAR_SM_4601777 (4/16)
Component Check Procedures
Section 7
12. Reinstall the wear
pad (C) and tighten
down using two allen
screws (D).
13. Reinstall the arm.
Wedging the arm up
on an angle may be
necessary to align
the link pin hole in
the arm with the
knuckle bushings.
Note:
Ensure that the pin
groove is on the same
side as the screw before
the installation.
14. Insert bushings back
into the arm link
and carefully thread
the link pin through
them and the other
side of the arm.
Tighthen the screw
once the link is in
place.
15. Power up the unit
and test to ensure it
is operating properly.